> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md).

# Glossary

A list of all definitions across tools.&#x20;

For a list of acronyms, please navigate to: [Acronyms](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions/acronyms.md)

## [<mark style="color:$primary;">A</mark>](#a)  [<mark style="color:$primary;">B</mark>](#b)  [<mark style="color:$primary;">C</mark>](#c)  [<mark style="color:$primary;">D</mark>](#d)  [<mark style="color:$primary;">E</mark>](#e)  [<mark style="color:$primary;">F</mark>](#f)  [<mark style="color:$primary;">G</mark>](#g)  [<mark style="color:$primary;">H</mark>](#h)  [<mark style="color:$primary;">I</mark>](#i)  [<mark style="color:$primary;">J</mark>](#j)  [<mark style="color:$primary;">K</mark>](#k)  [<mark style="color:$primary;">L</mark>](#l)  [<mark style="color:$primary;">M</mark>](#m)  [<mark style="color:$primary;">N</mark>](#n)  [<mark style="color:$primary;">O</mark>](#o)  [<mark style="color:$primary;">P</mark>](#p)  [<mark style="color:$primary;">Q</mark>](#q)  [<mark style="color:$primary;">R</mark>](#r)  [<mark style="color:$primary;">S</mark>](#s)  [<mark style="color:$primary;">T</mark>](#t)  [<mark style="color:$primary;">U</mark>](#u)  [<mark style="color:$primary;">V</mark>](#v)  [<mark style="color:$primary;">W</mark>](#w)  [<mark style="color:$primary;">X</mark>](#x)  [<mark style="color:$primary;">Y</mark>](#y)  [<mark style="color:$primary;">Z</mark>](#z)

***

## <mark style="color:$primary;">A</mark>

***

### Aboriginal participation

Where the credit refers to Aboriginal businesses or workforce targets, these also apply to Torres Strait Islander people.

***

### Accredited NABERS Assessor

An accredited individual authorised by NABERS to conduct NABERS Embodied Carbon ratings.

***

### Adaptive thermal comfort method

The Adaptive Thermal Comfort metric relates indoor design temperatures to outdoor temperatures. It is based on the understanding that occupants can adapt to, or even prefer a wider range of conditions.

***

### Adjacent site

Defined as within 100 m of the site boundary or as determined by an ecologist or regulatory authority.

***

### Air barrier system schematic

The schematic is to clearly define:

* Building envelope boundaries and any penetrations within these boundaries.
* Key testing / commissioning points, including source of pressurization, pressure measurement points and envelope areas.
* Expected relative pressures for each building compartment, including acceptable ranges. The schematic is to provide sufficient detail to assist in guiding the building pressure test process and to provide a clear design and acceptance criteria for the test.

***

### Air conditioning

Describes the control of the temperature, and where applicable humidity, within a conditioned space (as defined herein) by application of either or both mechanical heating and mechanical cooling. These may include one or more of combustion, refrigeration (including reverse-cycle operation), direct electric heating, evaporative cooling or other processes specifically for the purpose of controlling the temperature in one or more spaces in a building. The heating or cooling effect in the space may be remote from the actual heating or cooling plant, with one or more transport media, such as air, water or refrigerant, used to transfer heat between the conditioned space and plant. An air conditioning system may also provide mechanical ventilation, but this is not necessary for the system to be classified as air conditioning.

Unlike the NCC definition, for the purposes of Green Star, air conditioning includes any services that directly maintain specialised conditions for any equipment or process, if that equipment or process is within the scope of the Green Star rating (refer to Scope).

***

### Alternate refrigerants

This refers to a different refrigerant that is used in equipment of the same function, product category and capacity. The identified refrigerant(s) may be used in the same equipment in the Australian market or overseas.

***

### Annual peak electricity demand

The building's predicted annual peak electricity demand that is calculated as per the Energy Use calculation guide for the Energy Use credit. On-site renewable generation and energy storage is excluded.

***

### AR\&R (2019) Figure 9.4.3

Developed Catchment with Retention as Compared to Detention and Slow Drainage Strategies. For Volume Management for larger sensitive sites, outflow hydrograph resulting from modelling should be similar to that shown in Figure 9.4.3 (developed catchment with retention or rural catchments).

***

### Assessment

*Climate Change Resilience*\
In the context of this credit, assessment refers to the climate risk and adaptation assessment.

*Operations Resilience*\
In the context of this credit, assessment refers to the operations risk and adaptation assessment. (Operations resilience assessment in Buildings v1.1)

***

### Australian Rainfall & Runoff (AR\&R)

The Australian Rainfall & Runoff Guidelines: A Guide to Flood Estimation provides a detailed philosophy on Stormwater Volume Management within Chapter 4 of Book 9 Runoff in Urban Areas. The guide details volume management objectives and design considerations to control and reduce peak discharge from the site. While the guide provides design advice, information presented in the guide can be applied to existing buildings, when undertaking any upgrades to improve the stormwater management of the building.

***

### Automatic monitoring system

Automatic monitoring systems are defined as systems that record consumption and demand of energy, water, and indoor environment quality. These systems can process this information to produce reports at user adjustable intervals.

***

### Avoided trips

The propensity of employees to work from home or otherwise not take a commuting trip during a work week.

***

## <mark style="color:$primary;">B</mark>

***

### Baseload demand

The building's lowest point of electricity demand during operational hours.

***

### Base building

The portion of the building that is under the developer's scope of works when the building is tenanted. This includes common areas only.

***

### Battery energy storage systems

Battery energy storage systems (BESS) can be used on site to provide additional power to site where the grid connection is insufficient to power. Where these systems are used instead of a diesel generator, the electricity delivered to the BESS should be entered into the calculator in the 'Generator' category.

***

### Benchmark

A defined carbon emissions intensity based on building type. This is used in *Pathway A: Benchmark pathway* as the baseline from which the *Proposed building* is compared against.

***

### Biodiesel

A sustainable liquid fuel derived from vegetable oils or animal fats. It has physical properties similar to petroleum diesel, but it is a cleaner-burning renewable alternative. It can be used in many concentrations, from B5 (95% petroleum diesel & 5% biodiesel), all the way up to B100, which is pure biodiesel. This differs from renewable diesel.

***

### Biodiversity net gain

A measurable improvement in biodiversity condition and extent, above a defined baseline, resulting from development activities.

***

### Blackwater

Blackwater is water from kitchen sinks and toilets that is contaminated with human waste or food.

***

### Blue and Green Grid

A Blue and Green Grid is a strategy that aims to increase the interconnectedness of natural spaces within the urban environment. Projects should contact their local municipality to determine whether the project sits within a wider Blue or Green Grid strategy.

***

### Blue Grid

A Blue Grid specifically refers to the hydrological grid of a district. The Blue Grid offers an opportunity to use water systems as an interconnected network and improve the water and ecological quality of waterways along the entirety of the hydrological system. As per Sydney Green Grid: Spatial Framework and Project Opportunities, considerations for Blue Grids include:

* Permanent Water Bodies
* Wetlands
* Coastline
* Harbour and Estuaries
* Stormwater Infrastructure
* Catchment Data
* Easements
* Major Pipelines
* Stormwater Pits
* Streets

***

### Building materials

This includes any materials and products used on the building's structure, envelope, systems and finishes.

***

### Building owner's control

The scope of the project in which the building owner has decision making influence over.

***

### Building peak demand

The building's predicted annual peak electricity demand that is calculated as per the Energy Use calculation guide.

***

### Building's approval

This refers to the process which confirms the applicable version of the NCC that the project is subject to and must be reflected in the built outcome. The process differs between states however is generally when application for a construction approval is sought.

***

### Building services

This includes lighting, heating, ventilation, vertical transportation, acoustics, hydraulic, power supply, energy management and security and safety systems. Examples of systems making up the Building Services include, but are not limited to:

* Mechanical systems (such as HVAC and refrigeration systems; mechanically operable systems such as blinds and actuated shading devices).
* Building Management and Control System (BMCS).
* Lighting and associated controls.
* Electrical systems (such as electrical generation, electrical supply, distribution systems, security and access systems and alarm systems).
* Hydraulic systems (such as gas and water supply distribution systems, sewage collection and distribution systems, stormwater collection and distribution systems; pumps).
* Fire detection systems, smoke alarm systems and emergency warning systems.
* Fire protection systems, including pumps and other equipment.
* Lifts and any other vertical transport devices.
* Any other system that has an impact on the energy or water consumption of the building as identified by building owner or building operator.

***

### Building types which are purposely built for visitors

This refers to building types where the primary function is to accommodate and serve people that are not regular or permanent occupants. Examples of these building types include shopping centres, hotels, conference facilities, sport facilities and venues and hospitals.

***

## <mark style="color:$primary;">C</mark>

***

### Civil works

Civil works materials are defined as those that support the creation of roads, paths, paving, surfacing, fencing, railings, retaining walls, earthworks, landscaping and irrigation.

***

### Class 6 retail stores

This refers to standalone, free-standing retail buildings that do not share walls with adjacent buildings.

***

### Class 7b warehouses and cold stores

This refers to industrial buildings with logistics and distribution functions only. Industrial buildings that function primarily to manufacture or transform goods from one state to another are not eligible.

***

### Climate change variable

Variables relevant to the project on climate related issues such as: average temperature, extreme temperature, rainfall, extreme rainfall/flooding, storms, wind, bushfire, humidity, solar radiation, sea level rise, and ocean acidification.

***

### Co-design

Co-design is the approach of actively involving stakeholders in the design process. A successful co-design process is one that brings together a diverse group of stakeholders in an inclusive environment that fosters engagement to maximise outcomes.

***

### Cold shell

Where the finishes and services are not installed. A tenancy with an unfinished interior, with no HVAC services beyond the riser (or core or rigid duct), and without lighting, plumbing, ceilings, floor finishes (or with a setdown to allow for future provision of floor finishes), interior partitions or walls.

***

### Commissioner

The client, asset owner or other person or entity who commissions the Life Cycle Assessment.

***

### Communal Space

A space that is provided for community (i.e., public) usage free of charge.

***

### Community capacity building activity

An organised activity or gathering that brings together the surrounding local community, and the groups which rely on or interact directly or indirectly with the precinct.

***

### Community consultation

A process of two-way, informed communication to gain feedback and consensus on the Community Resilience Plan between the precinct owner and the community representative or community members.

***

### Conditioned space

A conditioned space is, as per the definition in the NCC, an internal space within a building, including a ceiling or under-floor supply air plenum or return air plenum, where the environment is likely, by the intended use of the space, to have its temperature controlled by air conditioning.

A conditioned space may use natural, mechanical or mixed-mode ventilation, but is always air conditioned (whether by design or intent).

***

### Construction and demolition waste

Materials generated during the demolition of existing structures and land clearing, and materials as result of construction of the precinct.

***

### Construction workforce

The construction workforce is defined as workers employed as part of the project and includes:

* Construction-related building, maintenance, and civil engineering.
* Construction-related support activities, such as financial, advisory, architectural, and professional services may be included where it is considered appropriate to achieve the policy objective.
* The construction workforce, including apprentices, trainees, and office support roles.

***

### Control Peak Discharge

This objective seeks to limit the peak flood flows and volumes discharging from a catchment. Changing the total volume of stormwater leaving a site (retention), or delaying the volume for a short period of time (hours) (detention or retarding) must be used to reduce the peak of the flood hydrograph discharging from a catchment. The acceptable discharge level is usually set at the natural or 'pre-development' condition. In some cases the acceptable level is below the natural condition (yield minimum) in order to achieve a net benefit or offset an impact elsewhere. In highly developed catchments (infill development), there are often existing piping and drainage assets below the site that cannot be practicably upgraded to accommodate the increased impervious areas. This credit requires a stormwater management design to reduce the volume and timing of stormwater discharges from the precinct. This combined approach is particularly relevant for managing stormwater runoff from increasing urban density (refer Book 9, Chapter 3). Volume reduction (retention) is required for inland catchments where there is a constrained floodplain downstream or sensitive waterway ecosystem that cannot accommodate increase in flooding frequency or volumes.

***

### Country

As defined in the Connecting with Country Framework, Country includes land, waters, and sky. It can be tangible or intangible aspects, knowledge and cultural practices, belonging and identity, wellbeing and relationships. People are part of Country and their wellbeing is intrinsically tied to its health and management.

***

### Critical equipment

The equipment that supports the occupant's access to basic needs and ensures their safety. These may include fire, ventilation, temperature control, hydraulics and telecommunication systems. The level of service of the systems does not need to be at full capacity if this is not required to service the needs of the occupants.

***

### Cultural competency training

*Buildings v1.1*\
Training that intends to build a greater understanding of First Nations culture to enhance people's capacity to engage effectively in an intercultural environment. The training is delivered online or in person by a First Nations provider. Examples include Centre for Cultural Competence Australia and the Australian Institute of Aboriginal and Torres Strait Islander Studies. The training can be self-led but also must include real-time reflection activities or assessment process to gauge participation. GBCA recommends that the training, where possible, is tailored to the specific Country the precinct is on.

*Communities v2*\
At a minimum, cultural competency training must be at least 10 hours, delivered online or in person by a recognised First Nations provider. Examples include Centre for Cultural Competence Australia and the Australian Institute of Aboriginal and Torres Strait Islander Studies. The training can be self-led but also must include real-time reflection activities or assessment process to gauge participation. GBCA recommends that the training, where possible, is tailored to the specific Country the precinct is on.

***

## <mark style="color:$primary;">D</mark>

***

### Decorative lighting fixtures

Lighting fixtures not required to achieve minimum lux requirements and not included in the lighting performance modelling.

***

### Deemed-to-Satisfy (DTS) provisions

Prescriptive provisions in the NCC which are deemed to satisfy the Performance Requirements.

***

### Default occupancy

Clean Air: Occupancy rates in accordance with Table A1 in Appendix A of AS 1668.2:2024. Movement and Place: For this credit, the default occupancy is 75% of the building population determined using NCC 2022 Section D2D18.

***

### Default occupancy period

The times where the spaces are occupied in accordance with the default operating profiles used for the Energy Use credit. Refer to GBCA's Energy Use calculation guide for further information.

***

### Dematerialisation

Reducing the quantity of materials used in a building while maintaining functionality and performance. This includes the quantity of waste produced during construction.

***

### Density

Urban density is a term that refers to the relationship between a physical area and the number of people who live in or make use of that area. Densification often goes under a number of pseudonyms, (including Compact City, Intensification, Agglomeration, Re-urbanisation and Urban Consolidation) all of which refer to much the same thing. It is often expressed as a ratio of population size or number of residential units' in a square kilometre.

***

### Design for disassembly

Creating buildings and components that can be easily recovered without damage, enabling reuse, recycling, or repurposing of materials.

***

### Design for flexibility

Creating buildings and spaces that can adapt to changing needs or functions over time, reducing the need for major alterations or demolition.

***

### Design for lifespan

Creating buildings and components that are durable, easy to maintain, and repairable to extend their useful life.

***

### Design for modularity

Creating buildings and components in standardised, prefabricated modules, that can be adjusted or reassembled to changing needs and functions over time without significant structural alterations.

***

### Design occupancy

The intended occupancy rate that the spaces have been designed for. Assumptions for the proposed occupancy rate are included in the project’s submission.

***

### Developer delivered buildings

All buildings that are delivered by the developer where they are in control of design and construction, regardless of whether control of the building is maintained once completed. These may include community buildings that are intended to be used for community purposes beyond precinct development such as (but not limited to) healthcare facilities (including childcare centres), sporting facilities, libraries, town hall facilities, cultural institutions, and/or sales or information offices. It also includes any permanent site office buildings.

***

### Disability enterprise

An Australian Disability Enterprise (ADE) is a not-for-profit organisation, with charitable status, which provides meaningful employment for people with significant disability who would otherwise not be able to work. It is a business that makes products or provides services.

***

### Display buildings

Typically, this would be a display home delivered by a volume home builder but there may be other display buildings depending on the precinct typology.

***

### Diverse expertise

When all members of the panel:

* Possess project-relevant skills and experience.
* Are recognised experts in their discipline, with a minimum of 10 years' experience.
* Are registered by a relevant professional peak body and are bound by that institutes' code of ethics in relation to objectivity, integrity, and accountability. The expertise of the panel is considered to be diverse when each member is an expert if a different discipline. Disciplines that are relevant to this credit include, but are not limited to, urban design, planning, architecture, landscape architecture, heritage architecture (if the project or the wider urban context features heritage elements), First Nations cultural heritage and transport planning.

***

### Diverse population

A diverse population includes individuals from a wide range of backgrounds, characteristics, and experiences. This diversity can encompass cultural background, gender identity, sexual orientation, age, abilities (physical, cognitive, sensory), socioeconomic status, education, and other aspects that contribute to the richness of the community. A diverse population reflects the varied identities and perspectives that exist within a society, fostering inclusivity and representation across different sectors.

***

### Dollar spent

Dollar spent relates to activities including: any construction, maintenance, rehabilitation, alteration, extension, or demolition of any improvements on land. It includes dollars spent on:

* Design and construction
* Tendering processes
* Project delivery
* Contract administration

***

### Ducted fan coil units

This is defined as:

* Proprietary packaged DX split systems, and variable refrigerant flow/variable refrigerant volume (VRF/VRV) systems;
* Proprietary packaged water-cooled heat pump fan coil units; and
* Proprietary packaged chilled water/heating hot water (CHW/HHW) fan coil units.

***

## <mark style="color:$primary;">E</mark>

***

### Early works

Works that are carried out prior to the main works (which would typically consist of the construction of the main building), often under a separate head contract.

***

### Eligible construction procurement

The following definition of construction from the Victorian Social Procurement Framework is being used. Dollar spent relates to activities including: any construction, maintenance, rehabilitation, alteration, extension, or demolition of any improvements on land. It includes dollars spent on:

* Design and construction.
* Tendering processes.
* Project delivery.
* Contract administration.

***

### Eligible First Nations procurement

Eligible spend includes First Nations employment, engagement of First Nations- owned businesses, education and training, and engagement or consultation with First Nations organisations or businesses.

***

### Embodied Carbon

Carbon emissions associated with materials and construction processes throughout the whole life cycle of a building. This includes Upfront Carbon, Use Stage Embodied Carbon, and End of Life Carbon, but not Operational Carbon.

<figure><img src="https://749968417-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FRL05MQuVhZhkDMQBuGrI%2Fuploads%2FWakSzzCJUevcTl2esMCy%2FGSBv1.1_CG_UC_fig1.png?alt=media&amp;token=af237afc-1c24-4b6f-ab82-ee028aa218c2" alt=""><figcaption></figcaption></figure>

*Figure - Embodied carbon through a building's life cycle (World Green Building Council, 2019)*

***

### Enclosed room

Enclosed room is defined as meeting rooms, private offices, classrooms, bathrooms, bedrooms, and any other similar space where it is expected that noise should not carry over from one space to the next. An enclosed room may be located within another enclosed room such as a bathroom within a Class 2 sole-occupancy unit or partition walls in a warehouse or office.

***

### End of Life Carbon

The carbon emissions associated with deconstruction/demolition, transport from site, waste processing and disposal phases of a building's life cycle which occur after its use (Modules C1 to C4).

***

### Energy

The type of resources that generate energy or electricity the building uses. This could be through renewable energy sources, such as solar PV, or grid electricity.

***

### Energy Use

Energy is defined as all electricity consumed, as well as any fuels burned on-site, or off-site, for power, heating, cooling, and cooking.

***

### Energy infrastructure

*Communities v2*\
This includes any district energy/heating, cooling systems, water and waste treatment plants, external lights, shared car parking including basement (not with separate title), security and communication infrastructure and any other shared facilities (e.g., public barbeques, toilets).

***

### Energy Use - National Construction Code&#x20;

Section J of the National Construction Code (NCC) Volume One (referenced as NCC Section J in this document) addresses energy efficiency requirements for Class 2 to 9 buildings and sets the minimum standard of performance required for the Reference building. The version of the NCC applicable to a project is the version referenced in the Building Certifier's report (or equivalent certifying authority) for projects registered to Green Star Buildings. This revision of the guide is based on NCC 2019 and where the NCC is referenced in this document the applicable version is the 2019 code or any later version which is current at the time of the project's registration. Projects registered to earlier versions of Green Star and certifying against earlier versions of the code are instructed not to use this revision of the guide.

***

### Envelope

The envelope is defined as the above ground elements that surround a building such as the façade, and all façade components such as external shading and insulation, as well as roofing systems.

***

### Excavation waste

Includes unwanted material resulting from excavation activities such as a reduced level dig and site preparation and levelling, and the excavation of foundations, basements, tunnels, and service trenches typically consisting of soil and stones.

***

### Excess energy distribution

Excess energy produced is distributed fairly across the grid, not to destroy the grid.

***

### Exercise room

A room that provides space for occupants to do physical activity at no cost to the occupants.

***

### External clothes drying facility

A zero-energy clothes drying facility, such as fixed or wall-mounted clothes lines, hoist, or similar equipment, that is in each apartment or as part of an on-site dedicated communal facility. The drying facility is located outdoors or in a naturally ventilated space in each apartment (e.g., balconies or bathrooms) and are purpose- built for drying and not incidental to other uses.

***

### External lighting

External lighting refers to lighting under the control of the building management. In addition to other types of external lighting, for the purposes of this credit luminaires inside glazed atria and those on the uppermost (uncovered) deck of an outdoor car park are external.

***

### External works

Refers to works completed outside the building footprint including landscaping, hardscaping, softscaping, infrastructure related to utilities and stormwater infrastructure.

***

## <mark style="color:$primary;">F</mark>

***

### Family restroom

A private toilet and washroom facility that can accommodate individuals, families with children and those with accessibility or assistance needs.

***

### Field of view

The area that is visible by an occupant from where the occupant is expected to be working or utilising the space.

***

### Finishes

Internal finishes include flooring, plasterboard, paints, ceilings, partitions, doors, insulation, glazing partitions or similar installed inside the envelope of the building. Joinery used as part of a wall finish is included, e.g., wall panelling or fixed shelving/cupboards that make up a partition. Sealants and adhesives used for finishes are also included. Loose furniture or joinery is not included.

***

### Fossil fuel free

Fossil fuel free energy includes electricity sourced from renewables, renewable hydrogen, renewable diesel and biodiesel. Avoided emissions (i.e., not having a specific high emitting construction activity occurring on-site) is excluded from this definition. The intent of the Leadership Challenge is to incentivise construction activities that produce a high amount of emissions to be fossil fuel free.

***

### Full time equivalent (FTE)

A full-time equivalent (FTE) is a unit of measurement used to determine the number of full-time hours worked by all employees on the project. The full-time hours for a job is based on the specified award rate for that job classification or an average of 7.6 hours/working day in the reporting period.

***

## <mark style="color:$primary;">G</mark>

***

### Gender diverse

Gender diverse refers to people who identify with a gender or genders outside of the binary of female and male.

***

### Gender-inclusive

Gender-inclusive refers to an approach that takes an inclusive view of gender, considering people of all genders and sexualities as well as intersections with factors such as race, ethnicity, income, class, age and ability.

***

### General waste materials

Includes all waste streams not clearly identified as being recyclable / reusable materials and resources.

***

### Green Grid

A Green Grid specifically refers to the ecological grid of a district. It attempts to protect and enhance the natural resources and biodiversity of the district by improving the quality of watercourses, creating green habitat corridors, and protecting endangered ecological communities. As per Sydney Green Grid: Spatial Framework and Project Opportunities, considerations for Green Grids include:

* Open space inventory
* Vegetation Mapping by State government department
* Vegetation Zones
* Metropolitan Bike Path Plan
* Regional Trails
* Streets
* Easements
* Major metro infrastructure
* Landform

***

### Green Roofs

A green roof is defined as a roof of a building that is partially or completely covered with vegetation and a growing medium.

***

### Greywater

Greywater can be recovered from sinks and showers, washing machines, cooling towers and other water sources that do not contain food or human waste.

***

### Grid maximum demand

The grid maximum demand is the window of time where the maximum electricity demand occurs, and is expected to occur, within a State or Territory. This is defined as:

* ACT, NSW, NT, QLD, SA, VIC & WA: 4 pm – 7 pm during summer months.
* Tasmania: 7 am – 10 am during winter months.

***

### Gross Floor Area (GFA)

As defined by the Australian Institute of Quantity Surveyors (AIQS) in the Australian Cost Management Manual – Volume 1 to be the sum of the fully enclosed covered areas (FECA) and unenclosed covered areas (UCA) of the building. Definitions for FECA and UCA below are extracted from the AIQS' Australian Cost Management Manual - Volume 1.

*Fully Enclosed Covered Area (FECA)*\
The sum of all such areas at all building floor levels, including basements (except unexcavated portions), floored roof spaces and attics, garages, penthouses, enclosed porches and attached enclosed covered ways alongside buildings, equipment rooms, lift shafts, vertical ducts, staircases and any other fully enclosed spaces and usable areas of the building, computed by measuring from the normal inside face of exterior walls but ignoring any projections such as plinths, columns, piers and the like which project from the normal inside face of exterior walls.

It shall not include open courts, light wells, connecting or isolated covered ways and net open areas of upper portions of rooms, lobbies, halls, interstitial spaces and the like which extend through the storey being computed.

*Unenclosed Covered Area (UCA)*\
The sum of all such areas at all building floor levels, including roofed balconies, open verandahs, porches and porticos, attached open covered ways alongside buildings, undercrofts and usable space under buildings, unenclosed access galleries (including ground floor) and any other trafficable covered areas of the building which are not totally enclosed by full height walls, computed by measuring the areas between the enclosing walls or balustrade (i.e. from the inside face of the UCA excluding the wall or balustrade thickness).

When the covering element (i.e. roof or upper floor) is supported by columns, is cantilevered or is suspended, or any combination of these, the measurements shall be taken to the edge of the paving or to the edge of the cover, whichever is the lesser.

UCA shall not include eaves overhangs, sun shading, awnings and the like where these do not relate to clearly defined trafficable covered areas, nor shall it include connecting or isolated covered ways.

In some credits, the exclusion of car parking (including undercover car parking) areas is specified however if not noted, the above definition applies.

***

### Gross residential density

The ratio of the number of dwellings to the area of land they occupy. The area includes internal public streets, all areas of local open space (including parks, sports fields, local or neighbourhood shops, primary and secondary schools, local community services, local employment areas and half the width of adjoining arterial roads.

***

## <mark style="color:$primary;">H</mark>

***

### Habitable room

The definition is as per NCC 2022 which states: A room used for normal domestic activities, and—

* a) includes a bedroom, living room, lounge room, music room, television room, kitchen, dining room, sewing room, study, playroom, family room, home theatre and sunroom; but
* b) excludes a bathroom, laundry, water closet, pantry, walk-in wardrobe, corridor, hallway, lobby, photographic darkroom, clothes-drying room, and other spaces of a specialised nature occupied neither frequently nor for extended periods.

***

### Harvest or Infiltrate Rainwater or Stormwater

This objective seeks to extract a proportion of the runoff volume from a catchment and either use this water for use in buildings and irrigation (i.e. consistent use to ensure draw down of storages), or infiltrate the runoff directly into local soils or subterranean aquifers (possibly for later trans-evaporation or extraction). These integrated design approaches can require interaction with soil properties, capacity of aquifers, urban form and demands of water (refer AR\&R Book 9, Chapter 3). The designer should account for the elements in the design of a catchment wide strategy to ensure that adequate storage space is available in storages to achieve the objectives of the strategy. Analysis of these measures must include continuous simulation and the use of full volume storms to understand the required storage capacity for a given set of rainfall events.

***

### Heat island effect

The heat island effect describes the condition where built-up areas have a higher average temperature than its rural surroundings owing to the make-up of the built environment.

***

### High emitting construction activity

A construction activity that typically emits a high amount of greenhouse gas emissions. The following activities are considered to be a high emitting construction activity:

* Demolition
* Earthworks
* Concrete pumping
* Piling and drilling
* Generators powering construction activities or site sheds
* Cranes

***

### High Quality External Views

A high quality internal view is defined as a view towards an area that is landscaped or contains a water feature, or an atrium. A landscaped area contains either high plant density, xeriscape gardens or arid climate landscaping. The landscaping may be horizontal or vertical.

***

## <mark style="color:$primary;">I</mark>

***

### Improve Water Quality

This objective seeks to reduce concentrations and loads of contaminants within urban runoff to pre-determined and acceptable levels. This is achieved by: diverting part of the stormwater on-site (retention) and passing the retained water through WSUD treatment processes where physical, chemical and biological processes reduce contaminants in the water. Harvesting (retention) and infiltration of stormwater can also provide some limited water quality treatment through settlement, soil natural attenuation after irrigation use, and diversion of pollutants to sewerage treatment.

***

### Independent commissioning agent

The ICA is defined as a person who is:

* An advocate for, and reports directly to, the project owner.
* Independent of any consultant, contractor or sub-contractor organisation that has been involved in the design or installation of the nominated systems.
* A registered professional engineer or qualified technician with demonstrated knowledge and competency of commissioning of each of the nominated systems and has previous experience with the commissioning process of at least 2 projects similar in scope (type, size and complexity). The qualified ICA role can be fulfilled by one or multiple persons, if all meet the requirements laid out above. It can also be fulfilled by a person who is part of the client's organisation if the person is qualified to do so. An independent commissioning company may also meet these requirements.

***

### Independent design review panel

Members of the panel are independent when they are not employed by the developer (and subsidiaries) or by any consulting organisations (and subsidiaries) involved in the project. The members have not worked on the project in previous years. Participation in the design review panel is not considered employment for this credit.

***

### Independent experienced individual

*LCA*\
Defined as an Experienced Individual who is:

* Not employed in a full-time or part-time role by the commissioner or practitioner of the LCA study.
* Not the practitioner of the LCA study.
* Not involved in defining the scope or conducting the LCA study.
* Has no direct or indirect incentive or interest linked to the outcome of the LCA results.&#x20;

*Impacts Disclosure*\
Defined as an Experienced Individual who is:

* Not employed in a full-time or part-time role by the commissioner or practitioner of the LCA study.
* Not the practitioner of the LCA study.
* Not involved in defining the scope or conducting the LCA study.
* Has no direct or indirect incentive or interest linked to the outcome of the LCA results.&#x20;

*Upfront Carbon Reduction*\
Pathway B: Reference building pathway: In the context of this credit, an independent experienced individual is a registered architect under the Australian Institute of Architects or a chartered engineer under Engineers Australia. Only the profession with the relevant expertise for the building elements that deviate from the Upfront Carbon calculation are required to conduct a review. An individual is independent if they are:

* Not employed in a full-time or part-time role by any members of the project team.
* Not involved in the project.
* Has no direct or indirect incentive or interest linked to the outcome of the project.

***

### Independent, accredited NABERS Assessor

An accredited NABERS Assessor, as defined above, that is

* Not employed in a full-time or part-time role by any members of the project team.
* Not involved in the project.
* Has no direct or indirect incentive or interest linked to the outcome of the project.

***

### Indigenous business

An Indigenous business is a legal entity that is majority owned by Aboriginal and/or Torres Strait Islanders persons and is engaging in productive activity and/or other forms of economic activity in the market sector.

***

### Indigenous or First Nations Cultural and Intellectual Property (ICIP)

Refers to the collective rights of First Nations Peoples to control the use, dissemination, and protection of their cultural knowledge, practices, symbols, and expressions.

***

### Indigenous plant

An indigenous plant is one that is found or occurs in a local area or region. A native plant can be one that is found in Australia, whereas an indigenous plant is found in a specific geographic location, such as a city or local government area.

***

### Internal views

A high-quality internal view is defined as a view towards an area that is landscaped or contains a water feature, or an atrium. A landscaped area must contain either high plant density, xeriscape gardens or arid climate landscaping. The landscaping may be horizontal or vertical.

***

## <mark style="color:$primary;">J</mark>

***

## <mark style="color:$primary;">K</mark>

***

### Key design project team organisation

Organisations central to the delivery of the design and construction of the project. This includes the developer, head contractor, architect, engineering and ESD consultant.

***

## <mark style="color:$primary;">L</mark>

***

### Laboratory equipment

This includes scientific equipment that uses fossil fuels for the purposes of education, research or for the manufacture of medicine or chemicals.

***

### Land/freshwater-use change metrics

The following metrics are referenced in the TNFD's [Additional sector guidance - Engineering, construction and real estate](https://tnfd.global/publication/additional-sector-guidance-engineering-construction-and-real-estate/)

<table><thead><tr><th width="104.5">Metric no.</th><th width="167.75">Indicator</th><th width="172">Metric</th><th>Metric description</th></tr></thead><tbody><tr><td rowspan="2">C1.0</td><td rowspan="2">Total spatial footprint</td><td>Total spatial footprint</td><td>Total spatial footprint (km2) (sum of):<br>• Total surface area controlled/managed by the organisation, where the organisation has control (km2);<br>• Total disturbed area (km2); and<br>• Total rehabilitated/restored area (km2).</td></tr><tr><td>Extent of land/freshwater ecosystem use change</td><td>Extent of land/freshwater ecosystem use change (km2) by:<br>• Type of ecosystem; and<br>• Type of business activity.</td></tr><tr><td rowspan="2">C1.1</td><td rowspan="2">Extent of land/freshwater/ocean-use change</td><td>Extent of land/freshwater ecosystem conserved or restored</td><td>Extent of land/freshwater ecosystem conserved or restored (km2), split into:<br>• Voluntary; and<br>• Required by statutes or regulations.</td></tr><tr><td>Extent of land/freshwater ecosystem that is sustainably managed</td><td>Extent of land/freshwater ecosystem that is sustainably managed (km2) by:<br>• Type of ecosystem; and<br>• Type of business activity.</td></tr></tbody></table>

***

### LCA certified practitioner

A person who is qualified as an "LCA Certified Practitioner" by ALCAS, LCANZ or ACLA, or another similar scheme.

***

### LCA experienced individual

An individual who has produced, co-produced and/or independently reviewed at least five LCA studies of precincts, buildings or building products in accordance with ISO 14040/14044, within the past three years.

***

### LCA peer review

A peer review is performed by an independent practitioner as stated in ISO 14044 Clauses 6.1 and 6.2, and in accordance with ISO/TS 14071. The review provides assurance of the credibility of the LCA and its results. The peer review aims to provide a third-party opinion on how the LCA was conducted and whether the results are acceptable to demonstrate credit compliance.

***

### Level of clothing (clo) and metabolic rates (met)

It is recommended that ASHRAE 55:2020 is utilized for Clothing level (clo) and Metabolic rate (met), when determining PMV levels in the reference, proposed building fabric and proposed building. Alternatively, the below figures can be used and justified how they apply to spaces where adopted.

<table data-search="false"><thead><tr><th>Building class space use</th><th>Clothing level (clo)</th><th>Metabolic rate (met)</th></tr></thead><tbody><tr><td>Class 2 &#x26; 3 – All living areas (Summer)</td><td>0.36</td><td>1.0</td></tr><tr><td>Class 2 &#x26; 3 – All living areas (Winter)</td><td>0.74</td><td>1.0</td></tr><tr><td>Class 5 – Office (Summer)</td><td>0.61</td><td>1.1</td></tr><tr><td>Class 5 – Office (Winter)</td><td>0.96</td><td>1.1</td></tr><tr><td>Class 6 – Shopping Centre (Summer clothing)</td><td>0.5</td><td>1.7</td></tr><tr><td>Class 6 – Shopping Centre (Winter clothing)</td><td>1.0</td><td>1.7</td></tr><tr><td>Class 7 – Distribution areas</td><td>0.96</td><td>2.1</td></tr><tr><td>Class 7 – Storage areas</td><td>0.96</td><td>1.7</td></tr></tbody></table>

***

### Life Cycle modules

The stages of a building's lifetime impacts as defined in EN15978 below

<figure><img src="https://749968417-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FRL05MQuVhZhkDMQBuGrI%2Fuploads%2Fnst2DSvDBzkffE1GGeuH%2FGSBv1_CG_CG_UC_fig2.png?alt=media&amp;token=5fdab9f4-803b-4d34-a3ae-8047774bffb1" alt=""><figcaption></figcaption></figure>

***

### Load diversity

The total expected power or "load" to be drawn during a peak period.

***

### Load shedding

Where electricity supply is reduced to customers when demand for electricity exceeds the available supply. Load Shedding is unplanned and can happen at a moment. Alternatives to load shedding include importing power from other jurisdictions, utilising emergency power reserves, appealing to customers to reduce consumption, or paying industrials users to power down for an amount of time.

***

### Long term population

The population size anticipated for the 10–15-year period beyond the end of the masterplan.

***

### Loss of distribution

Loss of electrical distribution within the precinct due to inadequate systems.

***

### Low global harm refrigerants

This refers to refrigerants with a GWP of less than 10 and that do not degrade to form TFA/PFAS.

***

## <mark style="color:$primary;">M</mark>

***

### Major energy uses

This should align with the major energy sources identified in the Metering and Monitoring criteria in Minimum Expectation in the Verification and Handover credits that are being metered and monitored.

***

### Manufactured commodities

In accordance with the TNFD, manufactured commodities include brick, cement, concrete, carpet, glass, insulation products, rubber and steel.

***

### Matters of National Environmental Significance

Matters of National Environmental Significance are protected against actions that have, or are likely to have, a significant impact by the Environmental Protection and Biodiversity Conservation Act 1999. Refer to Department of Climate Change, Energy, the Environment and Water (DCCEEW) for further information.

***

### Mode share

The proportion of commuting trips that take place by a given mode of transport (e.g. bus, car, bicycle).

***

## <mark style="color:$primary;">N</mark>

***

### Natural commodities

In accordance with the TNFD, natural commodities include aluminium, copper, gypsum, iron, lead, sand and timber.

***

### Net Lettable Area (NLA)

As defined by the Property Council of Australia (PCA) in the Method of Measurement: Commercial. NLA is defined as the sum of the whole floor lettable areas at each floor level. It is measured from the internal finish surface of permanent internal walls, but it includes structural columns or piers and small protuberances from the wall lines including window mullions and frames. Common areas part of the base build such as lift lobbies, stairs, plant rooms etc. are excluded.

***

### Net residential density

The ratio of the number of dwellings to the area of land they occupy including internal public streets, plus half the width of adjoining access roads that provide vehicular access to dwellings.

***

### Nominated building systems

Nominated building systems are defined by the project team. Examples of nominated building include, but are not limited to:

* Mechanical systems (such as HVAC and refrigeration systems; mechanically operable systems such as blinds and actuated shading devices).
* Building Management and Control System (BMCS).
* Lighting and associated controls.
* Electrical systems (such as electrical generation, electrical supply, distribution systems, security and access systems, and alarm systems).
* Hydraulic systems (such as gas and water supply distribution systems, sewage collection and distribution systems, stormwater collection and distribution systems; pumps).
* Fire detection systems, smoke alarm systems and emergency warning systems.
* Fire protection systems, including pumps and other equipment.
* Lifts and any other vertical transport devices.
* Any other system that has an impact on the energy or water consumption of the building, or impact on any other targeted credits within the Submission Guidelines, as identified by building owner or building operator.

***

### Nominated hours

Nominated hours are defined by the project team. The project team shall provide a summary of space types, uses, and nominated hours. For the Light Quality credit, projects that are operational outside of daylight hours only need to demonstrate compliance for operational daylight hours. These hours must align with any assumptions made within the credit.

***

### Nominated plane

For viewing facades (except skylights) the nominated plane is at ground level and is 1.5m wide band along the entire length of viewing façade, 1.5m in from the viewing façade. For skylights, the nominated plane is at ground level and consists of the projected area of the skylight and a surrounding 1.5m wide band.

***

### Normal operating conditions

Normal operating conditions refer to the ventilation mode that the space is designed for. For example, for mechanically ventilated spaces, the HVAC system is operating during normal hours or for naturally ventilated spaces, the windows are open.

***

### Number of occupants

This is based on the design occupancy which is the intended occupancy rate that the spaces have been designed for. The number of occupants that would be regularly occupying the building is to be consistent with the design occupancy assumed in other credits. Assumptions for the proposed occupancy rate are included in the project's submission. Where the design occupancy is unknown, a default occupancy that is 75% of the number of persons to be accommodated in accordance with NCC 2022 Section D Part D2D18(a).

***

## <mark style="color:$primary;">O</mark>

***

### Occupant

The number of occupants for the purposes of the Enjoyable Places credit is 75% of the number of persons to be accommodated in accordance with NCC 2022 Section D Part D2D18(a).

***

### Occupant amenity

Occupant amenity is defined as maintaining a similar level of operation as when the building is not load shedding. This includes temperature ranges being within the typical design days, all lighting being run, and vertical and horizontal transportation not being impaired. All other health and safety systems (hydraulic, fire, etc) are also functioning.

***

### Old growth forest

Defined by the National Forest Policy Statement as a forest that is ecologically mature and has been subjected to negligible unnatural disturbance such as logging, roading and clearing. The definition focuses on forest in which the upper stratum or overstorey is in the late mature to over-mature growth phases.

***

### Operational Carbon

The emissions associated with energy used to operate the building (Module B6). Operational water (Module B7) is also often included as part of Operational Carbon.

***

### Original Equipment Manufacturers

An Original Equipment Manufacturer is the company that produces the parts that may be used by another manufacturer. In the context of construction, the company that manufactures the construction machinery and equipment may be the same (e.g. a Volvo excavator contains a Volvo engine), or may differ from the company that makes the engine (e.g. a Putzmeister diesel concrete pump may contain a Caterpillar engine). The OEM refers to the company that makes the engine and is what is considered in the context for fossil fuel free construction and energy sources (biofuels, electricity, hydrogen used by the engine).

***

### Outdoor lighting

Outdoor lighting refers to lighting under the control of the building management. In addition to other types of external lighting, for the purposes of this credit luminaires inside glazed atria and those on the uppermost (uncovered) deck of an outdoor car park are external.

***

### Outdoor thermal comfort

Outdoor thermal comfort (OTC) is defined by a combination of factors both environmental and human based parameters.

***

### Outdoor user

Any outdoor user of the precinct sitting, walking, playing, pausing, and/or resting as relevant to the areas identified in the assessment.

***

### Owner's project requirements

* A common method for demonstrating that nominated building systems have been defined is through the owner's project requirements (OPR) document, or an equivalent document containing the same information. The OPR (or equivalent document) should be prepared by the design team and outline at least the following items:
* Description of the basic functions, operations, and maintenance of the nominated building systems, including:
* A description of its intended operation and maintenance requirements
* A list of what the main components are (including controls) and the importance of their efficient use.
* The targets for the energy and water consumptions and budgets for nominated building systems
* Description of how energy, water, and aspects of indoor environment quality are metered and monitored. This typically would include a meter diagram that illustrates how energy and water budgets could be confirmed in operation.

***

## <mark style="color:$primary;">P</mark>

***

### Parent room

A space for parents to undertake activities such as rest, change and care for children.

***

### Park sizes

* Small park: \~0.50 hectares.
* Local park: \~2.5 hectares.
* District park: \~10 hectares.
* Regional Park: \~30 hectares

***

### Peak solar generation period

The peak solar generation period is defined as 8 am – 4 pm.

***

### Personal protective equipment

Personal protective equipment (PPE) is defined as anything that needs to be worn to minimize risk to a worker's health and safety. In many instances PPE does not cater to different body types and shapes and in particular for women, they are ill fitting. This risks their health and safety. Examples of PPE include:

* Boots
* High visibility clothes
* Sun protection
* Gloves
* Safety harnesses
* Skin protection
* Goggles
* Safety shoes
* Hard Hats
* Hearing protection.

***

### Physically accessible

For outdoor planted areas to be considered physically accessible, the planted area is less than 20m from an entry or exit point and the occupants can physically interact with the planted area.

***

### Potable water

Water from ground or surface sources, treated to level that meets consumption standards.

***

### Practical Completion

Practical completion is achieved when all the necessary construction work is completed. The timing is defined by the occupancy certificate date of issue.

***

### Pre-development

Refers to the condition of the site prior to any development, i.e., the site is fully pervious.

***

### Precinct user

Any individual who regularly occupies or utilises any part of the precinct, such as owners, tenants, workers, residents, students and visitors. The composition of users varies based on the precinct's typology and intended use.

***

### Predicted mean vote (PMV) method

The PMV index predicts the mean response of a large group of people on a 7-point thermal sensation scale, from +3 (hot) to -3 (cold), where 0 is neutral. The metric is designed for fully mechanically ventilated buildings and is determined in accordance with ANSI/ASHRAE Standard 55. A PMV of -1 to +1 means that 80% of people are satisfied and comfortable.

***

### Prime Agricultural Land

Land of State, Regional or local significance for food production purposes due to its comparative advantage in terms of soils, climate, water (rain or irrigation) and access to services.

***

### Principal/Head contractor

A business or entity that manages and controls site work, typically construction work valued at $250,000 or more, engaged by the precinct developer. There could be multiple Principal/Head contractors overseeing different parts of a precinct or community development. Principal/Head contractors may also be responsible for demolition or civil works.

***

### Process loads

A process load is defined as the load on a project resulting from the consumption of energy by a manufacturing, industrial or commercial process, and are unrelated to lighting, heating, ventilation, cooling and water heating or the comfort of occupants.

***

### Product-as-a-service

Procurement of services rather than products. As the focus shifts from ownership to usage, users pay for the service of a product provides rather than ownership.

***

### Project boundary

Refers to the Green Star rating boundary.

***

### Project population

Refers to the population of regular building or fitout users within the project being rated. For example, in an education facility, the project population would include office staff or teachers and not visitor or student populations. This is on the basis that the ‘Sustainable Transport’ credit aims to capture the emissions attributed to the project being rated, and therefore, does not take into account visitor populations.

***

### Project scope

All areas and activities in a project that have been registered for Green Star. This includes all buildings and any ancillary areas such as parking, landscaping and shared facilities.

***

### Project site

Refers to the full site that the project is located on, ie. the area bounded by the site boundary.

***

### Proposed building&#x20;

The building to be rated by the Green Star rating tool, as designed by the project team.

For **Energy Use** in GSBv1: Modelling is undertaken in accordance with the Energy Use calculation guide where the below requirements are met:

* The performance of fan systems (J5.4), pump systems (J5.7), refrigerant chillers (J5.10) and heat rejection equipment (J5.12) must comply with the applicable efficiency requirements.
* The performance of artificial lighting systems (J6.2) must comply with the overall lighting efficiency requirement.
* Achieves thermal comfort requirements that complies with ASHRAE Standard 55 – 2020.

For **Upfront Carbon** in GSB v1: The building works to be rated by the *Green Star Buildings* rating tool, as designed and modelled by the project team as defined by the Green Star project scope.

***

### Proposed building fabric (formerly known as Intermediate Building under Design & As Built v1.3)

A hypothetical building of the same size, shape, floor area and same glazing shape and areas as the Proposed building, and including all the same building envelope design and performance characteristics as the proposed building, but building services characteristics and air temperatures (as nominated in the NCC)) are based predominantly on the NCC Section J Deemed-to-Satisfy provisions as defined in this document, and whose process energy consumption is based on appropriate benchmarks.

***

### Public open space

Space that is used for public and freely accessible recreation including parklands, sportsgrounds, beaches, gardens, riverbanks waterfronts, civic spaces, plazas and squares, rooftops and podiums.

***

### Public realm hardware

Public realm hardware is defined as outdoor furniture, lighting, signage, equipment and ornamental features installed in the streetscape, streets, parks, public amenities, recreational facilities, and/or playgrounds.

***

### Public spaces

Public spaces are areas open to the public, accessible and free to use including those spaces delivered or operated by a lot developer/owner. They may be located on publicly held land or privately held land that is owned and operated by private developers or companies.

***

### Public transport

Services run by government agencies or contracted to transport service providers.

***

### Publicly accessible areas

Areas of the building that can be accessed by the general public.

***

### Publicly available carparks

Those accessed freely by the public on either public or private land (e.g. within shopping centres).

***

## <mark style="color:$primary;">Q</mark>

***

### Qualified acoustic consultants

A Member or Fellow of the Australian Acoustical Society (MAAS, FAAS) or qualified staff member within an Association of Australasian Acoustical Consultants (AAAC) member firm. Alternative options can be considered through a Technical Question.

***

### Qualified civil engineer

A chartered civil engineer under Engineers Australia.

***

### Qualified ecologist

An Ecologist who has a degree in Ecology or similar and a minimum of five years continuous experience working as an ecologist.

***

### Qualified lighting professional

A professional who has a degree in lighting design or similar and a minimum of five years continuous experience working as a lighting designer.

***

### Qualified mechanical engineer

A chartered mechanical engineer under Engineers Australia.

***

### Qualified transport planner

The suitably qualified transport planner shall hold a relevant tertiary qualification (including, but not limited to, architecture, engineering, sustainability, and planning) and comply with at least one of the following:

* Minimum of five years' experience in transport planning.
* Has co-authored at least five building Sustainable Transport Plans / Green Travel Plans or similar.

***

### Quiet room

A space that provides auditory respite. Examples include pray/meditation/wellness rooms or contemplation spaces.

***

## <mark style="color:$primary;">R</mark>

***

### Rainwater

Rainwater refers to the water that arrives on the site through rain events, falling on roofs within the site boundary and captured through various types of systems.

***

### Reclaimed water

Reclaimed water refers to water that is recaptured, treated to some degree, and reused within a building.

***

### Recognised standard

\<u>\<em>Metering and monitoring attributes\</em>\</u>\<br> Alternatives to being pattern approved by the National Measurement Institute include:

* A test certificate from the European Measuring Instruments Directive - 2004/22/EC
* An accuracy certificate compliant to International Electrotechnical Commission (IEC) standards. \<u>\<em>Building commissioning\</em>\</u>\<br> Examples of a recognised commissioning standard or guideline include:
* AIRAH DA27 – Building Commissioning 2011
* ASHRAE Standard 202-2024 – The Commissioning Process Requirements for New Buildings and New Systems
* CIBSE – Commissioning Code M (and the ancillary codes for relevant services)
* SA TA 5342:2021 – Standards Australia Technical Specification for Building Commissioning

***

### Reconciliation Action Plan

“A RAP is a strategic document that supports an organisation’s business plan. It includes practical actions that will drive an organisation’s contribution to reconciliation both internally and in the communities in which it operates.” - Reconciliation Australia RAPs must be ratified and publicly noted on the Reconciliation Australia website to be viable for use. RAPs cannot be written by project teams without engagement from Reconciliation Australia.

***

### Recyclable / reusable materials

Materials that can be reused or be made into new products to prevent them from being sent to landfill.

***

### Recycled water

Recycled water refers to water that is treated at a centralized wastewater treatment plant and then made available for reuse, often through "purple pipe" systems.

***

### Reference building

A hypothetical project of the same size, shape, location, floor area and glazing areas as the proposed building. Refer to the Upfront Carbon calculation guide for further guidance.

***

### Reference project

A hypothetical building of a similar type located within the same Statistical Areas Level 2 (SA2) as that of the proposed project.

\
For **Upfront Carbon** in GSBv1: A hypothetical project of the same size, shape, location, floor area and glazing areas as the *Proposed Project*.

For **Water Use** in GSBv1: A hypothetical building of the same configuration and with the same facilities as the *Proposed building* but whose water supply services characteristics are based on a standard practice water efficiency and usage.

***

### Regime-in-balance

Harvesting, infiltrating or retaining the Stormwater runoff generated by the site for a nominated rain event (Usually a 20% AEP IFD) – above that occurring on the same site in the pre-development of natural catchment. Retention means to be fully retained for at least the duration of the lag time determined for the natural catchment. Lag time is the delay evident between the period of excess rainfall input to a catchment and its appearance as a surface runoff flood wave at the point of catchment discharge. The regime-in-balance strategy has two main applications. "Greenfields" catchments: equality of before-and-after surface runoff volumes – as defined above – in each element of a development enhances waterway development. Highly-developed catchments: application of before-and-after volume equality in each element of development/re-development reduces the need for downstream infrastructure augmentation.

***

### Registered community housing provider

The community housing provider is: a) A registered charity, where they are either registered community housing providers (CHPs); or have a primary purpose of providing housing to Aboriginal and/or Torres Strait Islander peoples. b) A State, Territory or Local Government organisation, or Government Housing Provider. c) A special purpose vehicle (SPV) with one of the eligible entities above as a member. In the case of SPVs, at least one of the members must be an eligible entity referred to in (a) and (b) above. The other members of the SPV do not need to be eligible entities, and therefore can include developers, investors, financiers, and other entities from the private, not-for-profit and non-government sectors. GBCA will require the eligible entity member (e.g., if it is a registered charitable CHP) to demonstrate that they have a meaningful participation role in the governance and operations of the SPV.

***

### Regular occupants

For the purpose of this credit, regular occupants are defined as staff or residents. Showers and lockers do not need to be provided for visitors. Customers or clientele are defined as visitors. Students in education facilities do not need to be included in the shower calculations but must have bicycle parking and lockers provided.

***

### Regularly occupied area

Clean Air, Light Quality, Connection to Nature: This is defined as areas of the building that are continuously occupied or occupied for more than two hours (previously known as 'primary' and 'secondary' spaces) including living and sleeping areas in Class 2 and Class 3 units. Cold shell retail and office areas are considered to be regularly occupied areas. Areas that are either transient or accessed intermittently such as corridors, storage, back of house or plant rooms can be excluded. Acoustic Comfort: This is defined as areas of the building that are continuously occupied or occupied for more than two hours (previously known as 'primary' and 'secondary' spaces in earlier Green Star rating tools) including living and sleeping areas in Class 2 and Class 3 units. Areas that are either transient or accessed intermittently such as corridors, storage, back of house or plant rooms can be excluded.

***

### Renewable diesel

An advanced biofuel made from renewable resources such as animal fats, vegetable oils and greases. It is chemically identical to conventional diesel, which allows the fuel to be integrated into existing engine infrastructure without any modification. It can be used in many concentrations, such as RD5 (95% petroleum diesel & 5% renewable diesel), all the way up to RD100, which is pure renewable diesel. Renewable diesel can be made from a wide range of feedstock. Only renewable diesel manufactured from biogenic feedstocks can be claimed as 'fossil fuel free'. Where waste tires or plastic are used to manufacture 'renewable diesel', it cannot be claimed as fossil fuel free for this credit.

***

### Renewable hydrogen

Renewable hydrogen is made from renewable energy and is used to fuel hydrogen and hydrogen fuel cell construction machinery.

***

### Resilience

Resilience is 'the ability of a system, community or society exposed to hazards to resist, absorb, accommodate, adapt, transform and recover from the effects of a hazard in a timely and efficient manner, including through the preservation and restoration of its essential basic structures and functions.' (UNDRR 2017).

***

### Responsible party

The Responsible Party is defined as the head contractor, principal contractor or similar. Where there are two parties, the responsible party is the one which carries the primary responsibility for implementing the EMS.

***

### Responsible Systems

Active building systems are characterised by energy and movement, and include all mechanical, hydraulic, transportation and electrical systems present in the building. Lighting, security, and fire systems are also included. Products that make up active systems such as pipes, cables, ducts etc are included. Passive systems such as a fixed façade shading device are not included.

***

### Reuse and adaptive reuse

Repurposing existing assets, materials or components from existing built assets to minimise demand for new resources.

***

### Reverberation

Reverberation time refers to the time taken for reverberantly decaying sound pressure level to decrease by 60 decibels in a room.

***

## <mark style="color:$primary;">S</mark>

***

### Schematic design

First phase in the design of a project where an Architect, Interior Designer or Engineer prepares drawings providing a general view of the components and the scale of the project based on the client brief.

***

### Sensitive sites

Sensitive sites are defined as:

* State, regional, or national protected areas.
* National or world heritage areas.
* Native, or primary, forests.
* Marine parks and land within a 'marine national park', 'conservation park', 'scientific research', 'preservation' or 'buffer' zone.
* Areas within declared fish habitat areas.
* Great Barrier Reef Marine Park.
* Water resources, watercourses, groundwater, or similar.
* Any wetlands of national importance listed under the Australian Ramsar Wetlands database, the Directory of Important Wetlands in Australia or wetlands deemed significant under a state register.
* Legally secured offset areas.
* Prime agricultural land.
* Sites that host in a permanent or migratory fashion any sensitive migratory species.
* Aspects considered 'Matters of National Environmental Significance' listed under the EPBC Act (regardless of whether they have been referred to the Federal Environment Minister for consideration and assessed as a 'controlled action' or not.)

***

### Sensitive species

Sensitive species are defined as:

* Ecological communities, habitats, flora, or fauna legally classified as endangered, critically endangered, of concern, or threatened in any federal or state register.
* Species that appear in the European Commission's 'Red list of endangered species' in a state, regional, national, or international databases.
* Listed migratory species (protected under international agreements).
* Listed marine species.

***

### Sensory room

A space that provides a calming and controlled sensory environment.

***

### Services infrastructure

Services infrastructure is defined as materials that are used for the precinct and buildings water, waste, electricity, telecommunications, traffic and street lighting connections.

***

### Shocks

Shocks - (acute) refer to large-scale high impact events and catastrophes such as man-made and natural disasters. Example shocks could include: bushfires, storms, floods, heatwaves, cyber-attack; digital network failure; terrorist attack; war and conflict, collapse of financial systems; natural disasters, widespread pandemics and/or diseases.

***

### Significant (nesting) tree

A large tree that can attain a height of minimum 15m or can be demonstrated to provide wildlife habitat.

***

### Significant impact

Significant impact is defined as a permanent reduction or loss of a species or of the biological and complexity of an ecosystem. This impact results in the long-term reduction of a species' capacity to continue to exist or impacts the capacity of biodiversity and ecosystem services to restore themselves. The Australian Government has a published guidance document outlining examples of significant impacts across several types of environmental impacts (Matters of National Environmental Significance - Significant impact guidelines 1.1). Significant impact is to be determined by a qualified ecologist with experience in the region based on the actions to be taken on site.

***

### Similar qualified professional

*Biodiversity Management Plan & Restoration and/or Management Plan*\
This is a professional with a formal tertiary qualification in natural sciences, environmental science, horticulture or landscape architecture with a minimum of five years' experience in biodiversity planning or preparing conservation management plans.

***

### Site boundary

Refers to the boundary that surrounds the total area owned by the building owner. This includes the building or buildings being developed, landscaping, car parking, ancillary infrastructure, and other existing buildings within a broader precinct owned by the building owner. This may be the same as the project boundary or larger due to the chosen project boundary or where there are existing buildings in a precinct.

***

### Site works

For this credit, this refers to any demolition, early works and/or main works that occurs after the purchase of the site until practical completion. Any works that occurred prior to the purchase of the site are excluded.

***

### Small buildings

Small buildings are defined as those with a Gross Floor Area (1000m2 excluding car parking) smaller than1000m2. Buildings with similar attributes to a small building that are outside the area definition can submit a Technical Question to obtain additional clarification.

***

### Social enterprise

Social enterprises are businesses that trade to intentionally tackle social problems, improve communities, provide people access to employment and training, or help the environment. They derive most of their income from trade (not donations or grants) and use the majority of their profits (at least 50%) to contribute to their social mission.

***

### Social Indicators

Social indicators are statistics within the community which can be used to determine the health and wellbeing of a community. Indicators such as quality of life, well-being, human development, economic prosperity, ecological sustainability can be used to gauge the health and wellbeing of a community.

***

### Social interaction room

A space that encourages social interaction and can be accessed by a diverse range of users. Examples include common rooms or staff lounge areas.

***

### Social procurement

Social procurement is the use of strategic procurement practice to generate social benefits beyond the products and services required. Social procurement occurs when organisations intentionally choose to purchase a social outcome when buying a good, service or delivering works.

***

### Social Value

Social value is the net positive change in social, environmental and economic wellbeing of those directly and indirectly impacted by an initiative, project, or organisation. In the built environment, social value is created when local needs are understood, the people most impacted are authentically engaged and where buildings, places, and infrastructure improve present and future communities' quality of life, wellbeing and social cohesion.

***

### Soil perviousness

Also known as permeability, soil perviousness is soil that offers a minimum resistance to the flow of water through it.

***

### Solar Reflectance Index (SRI)

The Solar Reflectance Index (SRI) is a composite measure of a material's Total Solar Reflectance (TSR) and thermal emittance. It is calculated in accordance with ASTM E1980-11. It is based on the material or product's emittance values and total solar reflectance. Material suppliers often provide SRI data for products. An initial SRI refers to the SRI of a new product. Over time the SRI of a product or surface will be reduced due to the material's exposure to the elements. The rate of degradation over time from such exposure is measured by the SRI of the product at three years.

***

### Sole-Occupancy Unit (SOU)

As defined by the NCC, a room or other part of a building for occupation by one or joint owner, lessee, tenant or other occupier.

***

### Special waste

Includes asbestos waste and asbestos containing material, or other hazardous waste and restricted solid waste as defined by the NSW Environment Protection Authority Environmental Guidelines and Policies for Waste.

***

### Statistical Area 2 (SA2)

A Census geographical unit representing a population of 3,000 to 25,000 people.

***

### Stored biogenic carbon

Carbon dioxide which is stored as biogenic carbon within the building for a minimum of 20 years.

***

### Stormwater

Stormwater refers to the water that arrives on the site through rain events, falling on hard surfaces other than roofs within the site boundary.

***

### Stressors

Stressors - (chronic) are often defined as the underlying 'slow burn' issues that have the potential to exacerbate a shock. Examples of stresses in the context of a city may include: social cohesion, housing affordability; access to transport; family violence, demand on health infrastructure; ageing populations, etc.

***

### Structure

The structure is defined as load bearing and stability components of a building, including load bearing elements in the superstructure and substructure. Temporary formwork is excluded from meeting compliance with the Responsible Products Value part of the credit, however, is included in the cost of the structure where projects choose to use the 'total cost' approach.

***

### Suitably qualified practitioner

*Airtightness*\
For the purposes of the Airtightness criterion, a suitably qualified practitioner is a member of the Air Tightness Testing and Measurement Association (ATTMA). The level of tester experience and qualification must be matched to the size and complexity of the project. For example, a Level 1 tester may be appropriate for small, simple enclosures requiring only one fan to test such as individual apartments, while a Level 2 tester may be required for larger, more complex enclosures requiring multiple fans to test, such as an entire apartment building tested at once. This requirement is intended to ensure a quality testing outcome given the testing practitioner's membership with an industry recognised body. For a current listing of members, please visit the ATTMA website. Should project teams wish to demonstrate an alternative yet equivalent qualification, a Technical Question must be submitted. GBCA also recommends project teams refer to guidance published by the ABCB in regard to practitioners qualified to sign off JV4 reports.

***

### Suitably qualified professional

*Biodiversity enhancement*\
For this credit, the suitably qualified professional can be an Ecologist, Horticulturalist or Landscape Architect who has a degree in Ecology or similar and/or a minimum of five years continuous experience working in their field.

*Climate Resilience*\
A professional with a formal tertiary qualification in a relevant field with a minimum of five years' experience in climate risk and adaptation assessments. This professional has experience undertaking AS/NZ ISO 31000:2009 Risk management processes.

*Community Resilience*\
This should comprise a professional with a formal tertiary qualification in environmental science or social sciences with a minimum five years' experience in resilience and adaptation assessment, or community engagement.

*Design for Equity*\
An individual with qualifications in urban planning, urban design, placemaking or similar with at least five years professional experience with demonstrated expertise in designing for equity and inclusion / co-design process (depending on the criteria the project is targeting).

*Operational Resilience*\
This should comprise a professional with a formal tertiary qualification in environmental science, risk management, or engineering with a minimum five years' experience in risk management or business continuity.

*Safe Places*\
An individual with qualifications in urban planning, urban design, placemaking or similar with at least five years professional experience with demonstrated expertise in design / co-design process (as relevant to the criteria the project is targeting).

*Streets for People*\
An individual with qualifications in urban planning, urban design, placemaking or similar with at least five years professional experience with demonstrated expertise in designing public places for people.

*Transport Planner*\
The individual shall hold a relevant tertiary qualification (including, but not limited to, architecture, engineering, sustainability, and planning) and comply with at least one of the following:

* Minimum five years' experience in transport planning
* Has co-authored at least five building Sustainable Transport Plans / Green Travel Plans or similar

***

### Sustainability education

This includes information on the certification of the space and other aspects of sustainability being implemented as part of the design and construction of the space. This could include skills development that contribute to overall project goals.

***

### System-level

In the context of this credit, this refers to the building as a system interacting with its surroundings. It does not refer to the mechanical building systems, such as HVAC.

***

## <mark style="color:$primary;">T</mark>

***

### Task areas

Areas where an occupant is expected to work or be stationary to focus on a specific task.

***

### Tenancy fitout guide

A guidance document that is provided to tenants and outlines the requirements and procedures tenants must include in their fitout design, construction and operations. It also includes information about the base building systems and performance. The requirement to meet the tenancy fitout guide is included in the lease agreement.

***

### Thermal comfort parameters

For the purposes of PMV calculation, thermal comfort parameters include:

* Air Temperature (°C)
* Air Speed (m/s)
* Relative Humidity (%)
* Mean Radiant Temperature (°C)
* Metabolic rates (met)
* Clothing Levels (clo)

***

### Threatened species

Threatened species includes those covered by the EPBC Act, State identified threated species and IUCN Status 1-4 threatened species.

***

### Total development area

The precinct's site area minus any excluded land.

***

### Total weighted average

The weighted average is calculated using the volume of initial charge as the weighting factor.

***

## <mark style="color:$primary;">U</mark>

***

### Universal Thermal Climate Index

Universal Thermal Climate Index (UTCI) relates to the body's physiological response to the thermal environment, in particular the synergistic heat exchanges between the thermal environment and the human body. It describes how the human body experiences atmospheric conditions, specifically air temperature, humidity, wind and radiation. UTCI is determined through an understanding of Air Temperature, Mean Radiant Temperature, Relative Humidity and Wind Speed. As the UTCI should represent the average conditions of a human within a given climate, a reference person shall need to be defined.

***

### Unshaded hardscape

Unshaded hardscape is defined as hardscape that is not shaded by vegetation or roof structures and includes roads, plazas, paths and open unshaded car parks and sports fields. Hard scaping excludes roof areas.

***

### Upfront carbon emissions

Upfront carbon emissions are those from modules A1 to A5 as defined in EN 15978.

***

### Upward light output ratio (ULOR)

The ratio of the luminous flux emitted by a luminaire above the horizontal to that emitted by the lamp.

***

### Use Stage Embodied Carbon

Emissions associated with materials and processes needed to maintain the building during use such as for maintenance, repair or refurbishments (EN 15978 Modules B1 to B5).

***

## <mark style="color:$primary;">V</mark>

***

### Vegetation

Vegetation is defined as landscaped areas, parkland, green space, and trees, whether new or pre-existing on the site. Shading from newly planted trees is measured based on predicted spread at five years after planting.

***

### Ventilation

**Natural ventilation**\
Describes the supply and/or exhaust of uncontrolled amounts of ventilation (outside) air by the use of openings in the building envelope (e.g. windows, non-powered ventilators and solar chimneys) which are connected to the conditioned space (as defined herein). The movement of air is controlled only by the prevailing environmental conditions, of which the main factors affecting ventilation are wind speed and direction, and temperature difference between indoors and outdoors. Openings may be automatically or manually controlled. Active heating or cooling may be present in Naturally Ventilated spaces but may be subject to additional requirements. Ceiling fans are not considered active heating or cooling for the purposes of Green Star.

**Mechanical ventilation**\
Describes the supply and/or exhaust of controlled amounts of ventilation (outside) air by the use of mechanical equipment, typically comprising fans, filters, ductwork and terminal air devices. The temperature of the supply ventilation air may be controlled, but this is not necessary for the system to be classified as mechanical ventilation. May apply to conditioned or unconditioned spaces.

**Mixed mode ventilation**\
Describes a building control strategy in which natural ventilation occurs during favourable conditions, and mechanical ventilation occurs independently or supplementally when natural ventilation cannot satisfy requirements. The mechanical ventilation mode is typically coupled with temperature control by air conditioning and operates independently of natural ventilation, but this is not always the case, and is not necessary for the system to be classified as mixed-mode.

***

### VOC test certificate

A test certificate that is from a laboratory accredited by National Association of Testing Authorities (NATA) or other ISO/IEC 17025 accredited laboratory. The test certificate includes:

* The numerical result
* The test method used to obtain the results
* For tinted products, the TVOC value must be inclusive of tints For paints, adhesives and sealants, a safety data sheet (SDS) that includes VOC information is also an acceptable test certificate. The TVOC content of the product is presented numerically in g/L of ready-to-use product and also includes a statement as to how the results was obtained, meaning either through experimental testing or theoretical calculations.

***

## <mark style="color:$primary;">W</mark>

***

### Waste specialist

A professional that is working for a waste consultant, building owner or waste contractor and has a minimum of three years' experience developing operational waste management plans.

***

### Water bodies and water courses

Water bodies and other permanent (non-ephemeral) watercourses are to be measured to the highest level of the water body or watercourse. Artificial pools are considered a water body.

***

### Water Efficiency Labelling and Standards (WELS) Scheme

The water efficiency of all fixtures and fittings sold in Australia is registered in the Water Efficiency Labelling and Standards (WELS) scheme. The WELS scheme awards each fixture or fitting with a star rating from one to six stars (with six representing the most efficient). The WELS ratings of all fittings and fixtures sold in Australia are publicly available from a database administrated by the federal government. The water consumption is displayed on the WELS label on the registered products.

For further information about the WELS rating scheme and the water efficiency thresholds for each star band, please refer to *AS/NZS 6400:2016 Water Efficient Products – Rating and Labelling* and [www.waterrating.gov.au](http://www.waterrating.gov.au).

***

### Water sensitive urban design (WSUD)

WSUD is a land planning and engineering design approach which integrates the urban water cycle, including stormwater, groundwater and wastewater management and water supply, into urban design to minimise environmental degradation and improve aesthetic and recreational appeal. This is also sometimes called Integrated Water Management (IWM).

***

### Women in non-traditional roles

A non-traditional trade or profession for women is where female participation is less than 25%.

***

### Workforce

The workforce to be considered in the workforce objectives and targets includes anyone employed as part of the project such as employees of the head contractor, subcontractor, professional services and design consultants. Workers on-site or in office support roles are included.

***

### Working plane

The horizontal plane above floor level in which the visual task lies. Recommended working plane heights in Table 3.2 in AS/NZS 1680.1 may be used. These are noted to be 0.7m for tasks at desk height and 0.85m for tasks at bench height. Alternatively, where furniture and joinery are provided, the height that the task will be performance may be used.

***

### Work weeks

This refers to the number of normal working weeks per annum for employees. This is separate from avoided trips which only refers to additional avoided trips.

***

## <mark style="color:$primary;">X</mark>

***

## <mark style="color:$primary;">Y</mark>

***

### Yield Minimum

Harvesting, infiltrating or retaining the Stormwater runoff generated by the site for a nominated rain event (Usually a 20% AEP IFD). The significantly smaller stormwater flow volumes coming from the precinct has a regenerative effect on the downstream catchments to help degraded rivers to recover and to reduce burden on already over capacity drainage infrastructure.

***

## <mark style="color:$primary;">Z</mark>

***

### Zero-emission

A zero-emission construction site requires all processes on the construction site to use zero emission technologies, such as battery or direct electrification or hydrogen. These technologies do not produce any carbon dioxide and they also reduce noise pollution. To maximise the reduction of lifecycle greenhouse gas emissions, zero emission machinery should be powered using renewable energy, which can include renewable electricity or renewable hydrogen.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.
