> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/places/27-or-movement-and-place.md).

# 27 | Movement and Place

Points: 3

## <mark style="color:$primary;">Outcome</mark>

The building's design and location encourage occupants and visitors to use active, low carbon, and public transport options instead of private vehicles.

## <mark style="color:$primary;">Criteria</mark>

<mark style="color:$success;">**Minimum Expectation — Nil**</mark>

* [#id-27.0.1-changing-facilities](#id-27.0.1-changing-facilities "mention"): The building includes showers and changing facilities for building occupants.
* [#id-27.0.2-accessible-inclusive-and-located-in-a-safe-and-protected-place](#id-27.0.2-accessible-inclusive-and-located-in-a-safe-and-protected-place "mention"): The facilities are accessible, inclusive, and located in a safe and protected space.

<mark style="color:$success;">**Credit Achievement — 3 points**</mark>

In addition to the *Minimum Expectation*:

* [#id-27.1.1-bicycle-parking-facilities](#id-27.1.1-bicycle-parking-facilities "mention"): The building's access prioritises cycling and includes bicycle parking facilities.
* [#id-27.1.2-sustainable-transport](#id-27.1.2-sustainable-transport "mention"): A Sustainable Transport Plan has been prepared and implemented.
* [#id-27.1.3-reducing-private-vehicle-use](#id-27.1.3-reducing-private-vehicle-use "mention"): The building has EV charging capabilities and transport options that reduce the need for private fossil fuel powered vehicles are prioritised.
* [#id-27.1.4-encouraging-walkability](#id-27.1.4-encouraging-walkability "mention"): The building's design and location encourage walking.

***

## <mark style="color:$primary;">Additional information</mark>

#### Stage implementation

**Strategy** | **Brief** | **Concept** | **Design** | **Tender** | **Construction** | Handover | Use

#### Synergies with other credits

* Community Resilience

#### Sustainable Development Goals

* **Goal 3:** Good Health and Wellbeing
* **Goal 11:** Sustainable Cities

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Minimum Expectation</mark>

The project must comply with **both** of the following criteria:

* Changing Facilities
* Accessible, Inclusive, and Located in a Safe and Protected Place

Classes 2 and 4 are exempt from these requirements.

Classes 3 and 9 are required to comply for staff only, not for short or long-term residents, visitors, or patients.

Classes 5, 6, 7b and 8 are required to comply for regular occupants, not for visitors.

#### 27.0.1 Changing Facilities

#### *Showers*

The design of the shower facilities must be appropriate to encourage their use. The project team is expected to justify how their location, locker sizes, privacy requirements, and size meet this aim.

The building must install showers based on the regular occupancy of the building:

<table><thead><tr><th width="236">Occupants</th><th>Showers</th></tr></thead><tbody><tr><td>0 - 49</td><td>1 Unisex</td></tr><tr><td>50-99</td><td>2</td></tr><tr><td>100 - 200</td><td>4</td></tr><tr><td>200+</td><td>Additional 1 per 200 occupants above 200</td></tr></tbody></table>

All showers must be at least 900 mm x 900 mm to enhance usability. Showers and bathrooms provided to meet statutory accessibility requirements do not count towards the minimum showers required to meet this Minimum Expectation.

Facilities should be located within easy access of the building and close to cycle parking (where provided).

#### *Lockers*

One locker must be provided for every eight regular building occupants or staff. The lockers must be secure and located in the changing rooms.

Lockers provided within tenancies, not in changing rooms, do not count toward this credit.

#### 27.0.2 Accessible, Inclusive, and Located in a Safe and Protected Place

Upon accessing, pedestrians and cyclists must be protected from the elements and other vehicles. Access must be safe, with consideration given to avoiding steep gradients, surface grip levels, and visibility around tight corners.

Access to the facilities must be well lit between entryway to bike parking, all amenities and lift lobbies and main access points to the building.

All regular building occupants or staff must have easy access to lockers, showers, and building entry. Occupants must be able to find the facilities thanks to clear signage throughout the building and access points.

### <mark style="color:$success;">Credit Achievement</mark>

In addition to the *Minimum Expectation*, the project must comply with **all four** of the following criteria:

* Bicycle Parking Facilities
* Sustainable Transport
* Reducing Private Vehicle Use
* Encouraging Walkability

#### 27.1.1 Bicycle Parking Facilities

The building's access must prioritise walking and cycling options. This means the building's access must be well lit, weather protected, and separated from vehicles. The building must also include access to bicycle parking facilities that are separated from the primary vehicle entrance to ensure safety.

Bicycle parking facilities must have signposted access to the changing rooms amenities as per the Minimum Expectation. The bicycle parking facilities must ensure the cycling equipment is safely secured. The amount of bicycle parking facilities is to be informed by the Sustainable Transport Plan.

In a residential building, the access points must connect to the relevant bicycle storage facilities. If these are at a unit level, the project team must show how the access won't be blocked by strata at a later date.

#### 27.1.2 Sustainable Transport

#### *Sustainable Transport Plan*

The project team must prepare and implement a Sustainable Transport Plan. The requirements or recommendations made in the Sustainable Transport Plan must then be reflected in the design of the building's facilities and ongoing operational processes.

As a minimum, the Sustainable Transport Plan must include all the following:

* A definition of the typical mode share of the development location and development type
* A target mode share for the development that prioritises active and public transport modes, and recommendations on how to achieve them
* Outline of how other modes of transport (carpooling, electric vehicles, and drop-off points) will be encouraged over private vehicle use
* Identification of future projects which may change or influence mode share (such as planned, or under construction infrastructure) and the year of completion for the new infrastructure
* Roles and responsibilities for implementing, monitoring, and auditing the Sustainable Transport Plan in the building's operational phase

The transport plan must be prepared by a suitably qualified Transport Planner or Engineer.

#### *Electric vehicle charging*

As a minimum, if the project scope includes parking, the building must provide:

* Ready to charge EV charging points to at least 5% of all car parking spaces.
* Connections for car sharing parking spaces, regardless of whether the vehicles are electric at the time of practical completion (in addition to the 5% provided)
* Electrical infrastructure and a load management plan prepared to allow for future installation of EV charging to 25% of all car parking spaces (including the minimum 5% and car share spaces already provided). The mix of EV chargers assumed (e.g., 7kW v 22 kW) must be stated.
* A dedicated, safe, unobstructed route from the electrical supply point which allows for the future provision of all necessary electrical cabling without the need for substantial builders work in connection to the electrical cabling installation.

As part of the Sustainable Transport Plan, the project team must outline how spatial and electrical barriers to the roll out of future provisions have been considered and addressed.

#### 27.1.3 Reducing Private Vehicle Use

Using the inputs from the Sustainable Transport Plan to complete the GBCA's Movement and Place calculator, the building's design and location must be shown to reduce emissions from transport, encourage public transport use, and reduce vehicle kilometres travelled compared to a reference building. The changes must be at least as follows:

* Emission reduction: 40%
* Active mode encouragement: 90%
* Vehicle Kilometres Travelled (VKT) reduction: 20%

#### 27.1.4 Encouraging Walkability

The building's design and location must encourage walking to and from a number of amenities. This means designing roads within the site boundary to prioritise pedestrians, and either providing within, or being located close to, a number of amenities.

#### *Roads*

If there are roads within the site boundary, the design must prioritise pedestrians over vehicles. Roads should be designed to be low speed (10km/hr). Pedestrians must have the right of way, and road design must encourage this.

#### *Amenity diversity*

Occupants should have access to a diversity of amenities across the below ten categories. There must be at least 10 amenities across five categories within 400m of the building, as determined by the Movement and Place calculator.

* Grocery: e.g., Convenience stores, supermarkets
* Health and wellbeing e.g., dentist, doctor, psychologist
* Food and Beverage: e.g., cafes, restaurants, bars
* Retail: e.g., clothing, homeware, hardware, book, gift stores
* Bank Services: e.g., banks, credit unions
* Education and Childcare: e.g., Primary, secondary, tertiary, or childcare facilities
* Recreation: e.g., movie theatres, fitness centres, swimming pools
* Public facilities: e.g., Libraries, local or state government service centres, post office
* Outdoor facilities: e.g., Playgrounds, parks
* Banking Services: e.g., ATM, bank branch

***

## <mark style="color:$primary;">Alternative pathways</mark>&#x20;

Where there are alternative pathways that a project can follow to achieve the credit, or sector specific alternatives.&#x20;

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Alternative pathways</summary>

#### <mark style="color:$primary;">**Green Star Buildings - Apartments Pathway**</mark>

{% hint style="info" %}
Please note that if this pathway is chosen, all credits that have an Apartments pathway must be followed. For more detail on what this includes, please navigate to<mark style="color:$success;">:</mark> [Apartments Pathway](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/apartments-pathway.md)
{% endhint %}

**Minimum Expectation — Nil:** Comply with both criteria:

* **Safe and protected access** — weather/vehicle protection, safe gradients and lighting, and clear wayfinding.
* **Electric vehicle charging** — via one of two routes:
  * *EV infrastructure* — ready-to-charge points for at least 5% of spaces or two visitor/shared spaces, NCC 2022 distribution/control provisions, cabling routes for future rollout, and a strata fund covering 80% of the cost of charging the remaining car parks; or
  * *EV chargers* — slow chargers across parking with demand management and at least basic Level 2 provision.

**Credit Achievement (Optional) — 3 points:** As per Green Star Buildings v1 submission guidelines; considered met where the Minimum Expectation is demonstrated.

Full requirements: [A27 | Movement and Place](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/apartments-pathway/categories-and-credits/places/a27-or-movement-and-place.md)

</details>

***

## <mark style="color:$primary;">Clarifications</mark>

Where GBCA have clarified any requirements of the credit criteria. This information is additional and it is not complusory to apply.

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Clarifications</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Submission content</mark>

#### Submissions for this credit must contain:

* **Submission form** through Green Star Online
* **Evidence** to support claims made in the submission
* **Movement and Place calculator**

#### Recommended evidence:

* Transport Drawings showing the provision and location of changing facilities
* As built drawings showing the number and size of showers, and of lockers
* Site drawings or as built drawings showing how the changing facilities are safe and protected
* Sustainable transport Plan including a site-specific transport assessment
* Site plans showing how pedestrian access has been prioritised
* As built drawings showing the number and location of bicycle parking facilities
* Manual calculations showing proximity to amenities

Alternate documentation can also be used by project teams to demonstrate compliance.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

The key requirement is that evidence is provided to support each claim made within the Submission form.

***

## <mark style="color:$primary;">Guidance</mark>

**Occupancy rates**\
When calculating occupancy rates, if the project design occupancy values are available prior to issuing of Tender documentation, these take precedence. When these are not available, the project should use the design occupancy (staff) estimation for their Development Application.

**Location of changing facilities**\
Facilities can be provided within the building's boundary, or outside. If the facilities are outside the site boundary, they must be within a reasonable walking distance, under the control of the building owner and be accessible to all building occupants (depending on the users being served by those facilities). Reasonable walking distance is defined as a five-minute walk or less.

**Changing facilities**\
The design of the shower facilities must be appropriate to encourage their use. The building should consider features such as ironing boards, iron, hanging racks, power points, mirrors, facial lighting, and any other facilities to encourage uptake. The project team is expected to justify how their location, locker sizes, privacy requirements, and size meet this aim.

**Load management plan & system**\
Load management systems should be hardware agnostic and localised to prevent building trips when communications drop out. The load management system should manage both AC and DC charging stations.

**Reference project**\
A hypothetical building of a similar type located within the same Statistical Areas Level 2 (SA2) as that of the proposed project.

**Cabling route for EVs**\
This may be achieved using any combination of electrical containment systems, such as electric cable ducting including drawstrings, electric cable trunking or conduits, or electric cable trays and cable ladders.

**Provision for EVs at practical completion**\
EV infrastructure should comply with all relevant Standards and health and safety legislation, be easily accessible and be located undercover. It is noted that trickle chargers, also referred to as occasional use chargers/ emergency chargers/ portable EV chargers which use a standard (three-prong) 220V plug are only recommended in urgent cases and therefore unsuitable to provide as a permanent EV charging solution for staff and visitors.

**Car share spaces**\
Car share spaces are dedicated to car share programs and cannot be used by private EVs. They require cables and a power outlet run to these spaces as a minimum. Kiosk (if required) can be installed once EVs are used in the car space.

**Suitably qualified transport planner**\
The suitably qualified transport planner shall hold a relevant tertiary qualification (including, but not limited to, architecture, engineering, sustainability, and planning) and comply with at least one of the following:

* Minimum five years' experience in transport planning
* Has co-authored at least five building Sustainable Transport Plans / Green Travel Plans or similar

**Calculation Guide**\
[Movement and Place calculation guide](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/calculation-guides/movement-and-place-calculation-guide.md)

***

## <mark style="color:$primary;">Definitions</mark>

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#regular-occupants)

Customers or clientele are defined as visitors.

Students in education facilities do not need to be included in the shower calculations but must have bicycle parking and lockers provided.

***

## <mark style="color:$primary;">Supporting information</mark>

The following resources support this credit:

* Electric Vehicle (EV) Charging Infrastructure Practice Note Nov 2018, Economic Development Queensland – QLD Government
* Electric Vehicle Council <https://electricvehiclecouncil.com.au/>
* Green Star Movement and Place calculator
* [Green Star Movement and Place calculation guide](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/calculation-guides/movement-and-place-calculation-guide.md)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/places/27-or-movement-and-place.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.