> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/positive/23-or-energy-source.md).

# 23 | Energy Source

Points: 6

## <mark style="color:$primary;">Outcome</mark>

The building's energy comes from renewables.

### <mark style="color:$primary;">Strategy</mark>

<table data-search="false"><thead><tr><th>Registration</th><th>Star rating</th><th>Requirement</th></tr></thead><tbody><tr><td rowspan="3"><strong>Registering from 2020 onwards</strong></td><td><strong>4 Star</strong></td><td rowspan="2">Meets the <em>Minimum Expectation</em></td></tr><tr><td><strong>5 Star</strong></td></tr><tr><td><strong>6 Star</strong></td><td>Meets the <em>Exceptional Performance</em></td></tr><tr><td rowspan="3"><strong>Registering from 2023 onwards</strong></td><td><strong>4 Star</strong></td><td>Meets the <em>Minimum Expectation</em></td></tr><tr><td><strong>5 Star</strong></td><td rowspan="2">Meets the <em>Exceptional Performance</em></td></tr><tr><td><strong>6 Star</strong></td></tr><tr><td><strong>Certified after 1st January 2030, regardless of registration date</strong></td><td><strong>All certifications</strong></td><td>Meets the <em>Exceptional Performance</em></td></tr></tbody></table>

## <mark style="color:$primary;">Criteria</mark>

<mark style="color:$success;">**Minimum Expectation — Nil**</mark>

* [#id-23.0.1-zero-carbon-action-plan](#id-23.0.1-zero-carbon-action-plan "mention"): The building provides a Zero Carbon Action Plan.

<mark style="color:$success;">**Credit Achievement — 3 points**</mark>

In conjunction with the *Minimum Expectation:*

* [#id-23.1.1-renewable-electricity](#id-23.1.1-renewable-electricity "mention"): 100% of the building's **electricity** comes from renewable electricity.

<mark style="color:$success;">**Exceptional Performance — 3 points**</mark>

**– Climate Positive Pathway –**

In conjunction with the *Credit Achievement:*

* [#id-23.2.1-renewable-energy](#id-23.2.1-renewable-energy "mention"): 100% of the building's **energy** comes from renewables.

***

## <mark style="color:$primary;">Additional information</mark>

#### Stage implementation

Strategy | **Brief** | **Concept** | **Design** | **Tender** | Construction | Handover | Use

#### Synergies with other credits

* Verification and Handover
* Life Cycle Impacts
* Energy Use
* Climate Change Resilience
* Operations Resilience

#### Sustainable Development Goals

* **Goal 7:** Affordable and Clean Energy
* **Goal 13:** Climate Action

#### Relevant reporting initiatives

* GRESB
* Task Force on Climate-related Financial Disclosures **(TCFD)**

#### Climate Positive Pathway – Leadership point

This credit is part of the Climate Positive Pathway in Green Star Buildings. When the pathway is achieved, a Leadership Challenge point is awarded to the building for a total of 15 points for this path.

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Minimum Expectation</mark>

The project must comply with the following criteria:

* Zero Carbon Action Plan

#### 23.0.1 Zero Carbon Action Plan

The project team must develop a Zero Carbon Action Plan for the building. The plan must be signed off by the building owner or developer and included in any operational documents for the building.

The Zero Carbon Action Plan must include a target date by when the building is expected to operate as fossil fuel free. The Zero Carbon Action Plan must cover all energy consumption, procurement, and generation and cannot rely on procuring renewable fuels as its only solution. It must also include infrastructure provided for tenants or future occupants such as gas installations for cooking.

The Zero Carbon Action Plan must be done prior to the tender phase of the project. The plan must:

* Quantify the building's scope 1 (including refrigerants) and 2 emissions between now and 2050 without any interventions
* Quantify the building scope 1 (including refrigerants) and 2 emissions in 2050 once all interventions have occurred
* Describe the changes the building is required to undertake to be climate positive as the distinct parts of the building's systems reach end of life
* Identify spatial considerations and physical interventions needed to replace fossil fuel using equipment, refrigerants, and infrastructure
* Perform a cost analysis of the potential costs and savings if the building was designed to be climate positive
* Be signed-off by the building owner or the developer

It must also outline, if relevant:

* A description of energy-consuming electrical, mechanical, or hydraulic systems and any refrigerants used.
* Any future spatial requirements or changes to plant rooms stemming from changes to existing building systems.
* Any additional capacity built into the building, substations, or building systems to enable any proposed changes. This may include the capacity to accommodate any future additional loads, energy storage or demand response solutions which may occur or be implemented during the life of the building.
* An upgrade or replacement timeline for the distinct systems, or system components, describing the point at which they are to be replaced with the appropriate alternatives.

The outcomes of the Zero Carbon Action Plan must be integrated with other Green Star credits targeted during certification. For example, any performance targets or activities relating the Zero Carbon Action Plan should be outlined in the *Verification and Handover* credit.

### <mark style="color:$success;">Credit Achievement</mark>

In conjunction with the *Minimum Expectation*, the project must comply with the following criteria:

* Renewable Electricity

#### 23.1.1 Renewable Electricity

All electricity under the control of the building owner or operator must be accounted for and sourced from renewables.

Electricity use for tenant loads is excluded from this credit.

Both on-site and off-site renewables are acceptable.

Where the project team claims the credit through off-site renewables, the building owner must sign a renewable energy contract. The shortest contract length is:

* Five years
* Where the building is owned and managed by an entity that has signed to the Global Commitment for Net Zero Carbon Buildings managed by WorldGBC, the shortest contract length is three years. Other commitments may be acceptable through a Technical Question.

The contract can be part of a corporate power purchasing agreement for a building portfolio.

Refer to the *Climate positive buildings and our net zero ambitions document* for more information on suitable options recognised by Green Star.

### <mark style="color:$success;">Exceptional Performance</mark>

In conjunction with the *Credit Achievement*, the project must comply with the following criteria:

* Renewable Energy

#### 23.2.1 Renewable Energy

All energy under the control of the building owner/operator and all non-electricity energy provided for uses that are not under the building owner's control must be sourced from renewables.

Fossil fuels cannot be used on site for any domestic hot water, space heating or cooking under any circumstances regardless of base build or tenant use. Fossil fuels for industrial processes are excluded from the assessment.

Any fossil fuels used for emergency power or laboratory equipment must be less than 1% of the total building energy consumption and be offset for the first five years of operation.

Both on-site and off-site renewables are acceptable.

Where the project team claims the credit through off-site renewables, the building owner must sign a renewable energy contract. The shortest contract length is:

* Five years
* Where the building is owned and managed by an entity that has signed to the Global Commitment for Net Zero Carbon Buildings managed by WorldGBC, the shortest contract length is three years. Other commitments may be acceptable through a Technical Question.

The contract can be part of a corporate power purchasing agreement for a building portfolio.

Refer to the *Climate positive buildings* and our net zero ambitions document for more information on suitable options recognised by Green Star.

***

## <mark style="color:$primary;">Alternative pathways</mark>&#x20;

Where there are alternative pathways that a project can follow to achieve the credit, or sector specific alternatives.&#x20;

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Alternative pathways</summary>

#### <mark style="color:$primary;">**Green Star Buildings - Apartments Pathway**</mark>

{% hint style="info" %}
Please note that if this pathway is chosen, all credits that have an Apartments pathway must be followed. For more detail on what this includes, please navigate to<mark style="color:$success;">:</mark> [Apartments Pathway](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/apartments-pathway.md)
{% endhint %}

**Minimum Expectation — Nil:** Fossil-fuel free — all electric, with no gas infrastructure connected for hot water, space heating or cooking.

**Credit Achievement (Mandatory) — 3 points:** 100% of common-area electricity from renewables (on-site or off-site, with minimum contract terms for off-site supply).

**Exceptional Performance (Mandatory) — 3 points:** In conjunction with Credit Achievement:

* **Renewable electricity mechanism** — the building owner provides and actively promotes a mechanism for residents to procure renewable electricity for their own apartments.
* **Engagement activities** — a resident campaign on reducing energy use, eliminating fossil fuels, and procuring renewables.

Full requirement: [A23 | Energy Source](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/apartments-pathway/categories-and-credits/positive/a23-or-energy-source.md)

***

#### <mark style="color:$primary;">Tenant Energy Source - Sector Specific Credit</mark>

Available to buildings where more than 20% of GFA is leased to tenants (e.g. office, retail, industrial, residential).

**Credit Achievement (Mandatory) — 2 points:**

* **Renewable electricity mechanism** — the building owner actively assists tenants to procure renewable electricity.
* **Engagement activities** with tenants.
* **Engaged tenants** — at least 40% of tenant space (by NLA) uses 100% renewable electricity.

**Exceptional Performance (Optional) — 3 points:**

* **Renewable electricity** — at least 80% of tenant space (by NLA) uses 100% renewable energy.
* **Fossil fuel use** addressed across tenancies.

Full requirement: [Tenant Energy Source](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/sector-specific-credits/tenant-energy-source.md)

***

#### <mark style="color:$primary;">Energy Source – Industrial - Sector Specific Credit</mark>

Available to industrial buildings leased to tenants (e.g. distribution centres, storage warehouses, manufacturing). Alternative to the Energy Source credit — cannot be claimed in addition to it.

**Minimum Expectation — Nil:**

* **Zero Carbon Action Plan** for the building.

**Credit Achievement (Mandatory) — 3 points**: In conjunction with the Minimum Expectation:

* **Fossil fuel free building** — for cooking, heating and domestic hot water.
* **Design for fuel switching** — future-proofed for fossil-fuel-free energy to all process loads.
* **Electric fleet** — capacity for an electric fleet servicing the building's onsite operations.

**Exceptional Performance (Optional) — 3 points** (Climate Positive Pathway): In addition to the Credit Achievement:

* **Renewable electricity** — 100% of electricity under the building owner's control from renewables.
* **Tenant engagement** to source renewable energy.

Full requirements: [Energy Source - Industrial](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/sector-specific-credits/energy-source-industrial.md)

***

#### <mark style="color:$primary;">Tenant Energy Source – Industrial - Sector Specific Credit</mark>

Available to industrial buildings leased to tenants (e.g. distribution centres, storage warehouses, manufacturing). Alternative to the Tenant Energy Source credit — cannot be claimed in addition to it.

**Credit Achievement (Mandatory) — 2 points:**

* **Zero Carbon Action Pla**n for all tenant energy use, including process loads.
* **Renewable electricity** — 100% of the electricity used by the tenant is renewable.

**Exceptional Performance (Optional) — 3 points:**

* **Renewable energy** — 100% of the energy used by the tenant is renewable, including process loads.

Full requirements: [Tenant Energy Source - Industrial](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/sector-specific-credits/tenant-energy-source-industrial.md)

***

</details>

***

## <mark style="color:$primary;">Clarifications</mark>

Where GBCA have clarified any requirements of the credit criteria. This information is additional and it is not complusory to apply.

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Clarifications</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Submission content</mark>

#### Submissions for this credit must contain:

* **Submission for**m through Green Star Online
* **Evidence** to support claims made in the submission

#### Recommended evidence:

* Zero Carbon Action Plan with supporting evidence
* Signed PPA including extracts on the length of contract
* Evidence that the PPA or on-site generation covers 100% of electricity or energy
* Public commitment to the Global Commitment for Net Zero Carbon Buildings managed by WorldGBC

Alternate documentation can also be used by project teams to demonstrate compliance.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

The key requirement is that evidence is provided to support each claim made within the Submission form.

***

## <mark style="color:$primary;">Guidance</mark>

**Applicability**\
This credit applies to all building sectors. For industrial buildings and other building types where the building owner doesn't retain operational control of the site, the scope is all electricity and energy as required to be accounted for in the Energy Use credit.

**Exceptions**\
This credit does not address gas use for manufacturing or research purposes. GBCA encourages project teams to look at how to decarbonise these loads as part of the development of the project. However, as these aren't building loads, these are not eligible for a market transformation claim.

A small amount of fossil fuels can be allowed in extenuating circumstances, such as a laboratory or emergency purposes. A Technical Question must be submitted to the GBCA for approval, prior to submission, outlining how there are no viable commercial alternatives. In this case, the building applicant must buy carbon offsets equal to 5 years of fossil fuel emissions. See the Climate Positive buildings and our net zero ambitions for more information on acceptable offsets.

The GBCA notes that gas cooking for retail has viable commercial alternatives.

**Offsets**\
See Climate positive buildings and our net zero ambitions document available from Green Star resources for more information on acceptable offsets.

**Green Star rating and renewable energy**\
Where the building's energy use comes from renewables, the Green Star certificate will note that the building's rating is valid provided the procurement of renewable electricity or energy continues. Should the building not continue to be powered by renewables, the building owner can no longer communicate the rating.

**Renewable electricity**\
The building is considered to have all of its electricity considered as renewables if the sum of all renewable energy generated on-site and off-site is equal to, or greater than, the total electricity use of the building annually.

**Market-based method and the renewable power percentage (RPP)**\
Project teams can claim the percentage of renewable energy in the grid (the RPP) as published by the Clean Energy Regulator at the date of Practical Completion of the building as off-site renewable energy supply.

For further information, refer <https://cer.gov.au/schemes/renewable-energy-target/renewable-energy-target-liability-and-exemptions/renewable-power-percentage>

Projects located in ACT where the state government has purchased 100% Green Power can claim this as off-site renewable electricity.

***

## <mark style="color:$primary;">Supporting information</mark>

The following resources support this credit:

* GBCA's Climate positive and our net zero ambitions
* [GBCA's Climate Positive Roadmap](https://gbca-web.s3.amazonaws.com/media/documents/carbon-positive-roadmap-discussion-paper-rev-a.pdf)
* World GBC's [Net Zero Carbon Buildings Commitments](https://worldgbc.org/thecommitment/)
* Clean Energy Regulator's [Renewable Power Percentage](https://cer.gov.au/schemes/renewable-energy-target/renewable-energy-target-liability-and-exemptions/renewable-power-percentage)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/positive/23-or-energy-source.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.