> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/positive/24-or-other-carbon-emissions.md).

# 24 | Other Carbon Emissions

Points: 4

## <mark style="color:$primary;">Outcome</mark>

The building's emissions from refrigerants, upfront carbon, and remaining carbon sources are eliminated or offset.

### <mark style="color:$primary;">Strategy</mark>

<table data-search="false"><thead><tr><th>Registration</th><th>Star rating</th><th>Requirement</th></tr></thead><tbody><tr><td rowspan="3"><strong>Registering from 2020 onwards</strong></td><td><strong>4 Star</strong></td><td rowspan="2">Optional</td></tr><tr><td><strong>5 Star</strong></td></tr><tr><td><strong>6 Star</strong></td><td>Meets the <em>Credit Achievement</em></td></tr><tr><td rowspan="3"><strong>Registering from 2023 onwards</strong></td><td><strong>4 Star</strong></td><td>Optional</td></tr><tr><td><strong>5 Star</strong></td><td>Meets the <em>Credit Achievement</em></td></tr><tr><td><strong>6 Star</strong></td><td>Meets the <em>Exceptional Performance</em></td></tr><tr><td><strong>Certified after 1st January 2030, regardless of registration date</strong></td><td><strong>All certifications</strong></td><td>Meets the <em>Exceptional Performance</em></td></tr></tbody></table>

## <mark style="color:$primary;">Criteria</mark>

<mark style="color:$success;">**Credit Achievement — 2 points**</mark>

**– Climate Positive Pathway –**

* [#id-24.1.1-eliminating-refrigerants](#id-24.1.1-eliminating-refrigerants "mention"): The building owner eliminates emissions from refrigerants. or
* [#id-24.1.2-offsetting-refrigerants](#id-24.1.2-offsetting-refrigerants "mention"): The building owner offsets emissions from refrigerants.

<mark style="color:$success;">**Exceptional Performance — 2 points**</mark>

In addition to the *Credit Achievement:*

* [#id-24.2.1-other-emissions](#id-24.2.1-other-emissions "mention"): All other emissions not captured in the Positive category are eliminated or offset.

***

## <mark style="color:$primary;">Additional information</mark>

#### Stage implementation

Strategy | Brief | **Concept** | **Design** | **Tender** | **Construction** | Handover | Use

#### Synergies with other credits

* Energy Source
* Life Cycle Impacts
* Upfront Carbon Emissions

#### Sustainable Development Goals

* **Goal 7:** Affordable and Clean Energy
* **Goal 13:** Climate Action

#### Relevant reporting initiatives

* GRESB
* Task Force on Climate-related Financial Disclosures **(TCFD)**

#### Climate Positive Pathway – Leadership point

This credit is part of the Climate Positive Pathway in Green Star Buildings. When the pathway is achieved, a Leadership Challenge point is awarded to the building for a total of 15 points for this path.

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Credit Achievement</mark>

The project must comply with **one** of the following criteria:

* Eliminating Refrigerants
* Offsetting Refrigerants

All refrigerants from building systems or domestic appliances provided by the building must be captured in the credit. This includes where fridges or freezers are provided as part of a fitout package in a residential setting.

#### 24.1.1 Eliminating refrigerants

High-GWP refrigerants must be eliminated from the building. The use of refrigerants with a GWP of 10 or less is considered to comply with the credit. Natural refrigerants in most cases comply with this criterion.

#### 24.1.2 Offsetting Refrigerants

100% of carbon emissions from refrigerants must be offset.

Carbon emissions are calculated by multiplying the initial refrigerant charge by its Global Warming Potential (GWP) for each type of refrigerant present in the building and adding the emissions together.

See *Climate positive buildings and our net zero ambitions* document available from Green Star resources for more information on acceptable offsets.

### <mark style="color:$success;">Exceptional Performance</mark>

In addition to the *Credit Achievement,* the project must comply with the following criteria:

* Other Emissions

#### 24.2.1 Other Emissions

The project team must calculate and offset:

* Emissions from the building's electricity use (as determined in the Energy Use credit) multiplied by the grid emissions factor (unless the Energy Source Credit Achievement is met, in which case these emissions are zero)
* Emissions from the building's energy use as determined in the Energy Use credit (unless the Energy Source Exceptional Performance is met, in which case these emissions are zero)
* The Climate Change impact category for modules A1 – A5
* Any other carbon emissions over 1% of the total carbon emissions profile for the building (significant emissions).

#### *Alternative calculation method for Exceptional Performance*

As an alternative path to calculating emissions from:

* Emissions from module A4 and A5 construction equipment use, and utilities during construction on site
* Construction waste emissions

The building owner can make an additional offset purchase equal to 5 years of modelled operational energy use (from the Energy Use credit), multiplied by the current grid coefficient to cover additional emissions not captured by any other calculation. These are not offsets for future operational use, rather they address emissions related to other carbon sources not already captured.

***

## <mark style="color:$primary;">Alternative pathways</mark>&#x20;

Where there are alternative pathways that a project can follow to achieve the credit, or sector specific alternatives.&#x20;

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Alternative pathways</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Clarifications</mark>

Where GBCA have clarified any requirements of the credit criteria. This information is additional and it is not complusory to apply.

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Clarifications</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Submission content</mark>

#### Submissions for this credit must contain:

* **Submission form** through Green Star Online
* **Evidence** to support claims made in the submission

#### Recommended evidence:

* Confirmation that refrigerants have been eliminated from the building along with supporting documentation (e.g., mechanical as built drawings)
* Calculations showing the total refrigerant charge to be offset
* Evidence of purchase of offsets (e.g., contract) clearly showing the length of offset
* Overview of the remaining carbon emissions and evidence of their offset

Alternate documentation can also be used by project teams to demonstrate compliance.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

The key requirement is that evidence is provided to support each claim made within the Submission form.

***

## <mark style="color:$primary;">Guidance</mark>

**Excluded equipment**\
Where specialty medical or manufacturing equipment exists, project teams should submit a Technical Question to the GBCA if they intend to exclude such equipment from the calculations.

**Offsets**\
Refer to the Climate positive buildings and our net zero ambitions document for more information on eligible offsets.

**Refrigerants**\
Hydrofluorocarbon (HFC) refrigerants are synthetic greenhouse gases, primarily used in refrigeration and air-conditioning equipment and generally have a high global warming potential (GWP). GWP is the relative amount of degradation the refrigerant can cause to global warming.

Under the Ozone Protection and Synthetic Greenhouse Gas Management legislation, it is an offence to discharge HFC refrigerant into the atmosphere, specifying that the refrigerant recovery process must be undertaken, and the recovered refrigerant stored and disposed of by an authorized business. With this in mind, building owner must consider the requirements for future disposal of HFC at the end of equipment life.

Several suitable alternatives with no or very low global warming potential are available in Australia, including ammonia, carbon dioxide, hydrocarbons and hydrofluoroolefins (HFOS). Not all HVAC systems can use low GWP refrigerants in Australia at this point however products are in development; project teams must still comply with requirement to offset initial charges of high GWP refrigerants. GBCA recommends talking further with product manufacturers.

***

## <mark style="color:$primary;">Definitions</mark>

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#energy)

***

## <mark style="color:$primary;">Supporting information</mark>

The following resources support this credit:

* GBCA's Climate positive buildings and our net zero ambitions
* [GBCA's Climate Positive Roadmap](https://gbca-web.s3.amazonaws.com/media/documents/carbon-positive-roadmap-discussion-paper-rev-a.pdf)
* World GBC's [Net Zero Carbon Buildings Commitments](https://worldgbc.org/thecommitment/)
* Clean Energy Regulator's [Renewable Power Percentage](https://cer.gov.au/schemes/renewable-energy-target/renewable-energy-target-liability-and-exemptions/renewable-power-percentage)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/positive/24-or-other-carbon-emissions.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.