> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/positive/26-or-life-cycle-impacts.md).

# 26 | Life Cycle Impacts

## <mark style="color:$primary;">Outcome</mark>

The building has lower environmental impacts from resource use over its lifespan than a typical building.

## <mark style="color:$primary;">Criteria</mark>

<mark style="color:$success;">**Credit Achievement — 2 points**</mark>

* [#id-26.1.1-life-cycle-assessment](#id-26.1.1-life-cycle-assessment "mention")The project demonstrates a 30% reduction in life cycle impacts when compared to standard practice.

***

## <mark style="color:$primary;">Additional information</mark>

#### Stage implementation

**Strategy** | **Brief** | **Concept** | **Design** | **Tender** | **Construction** | Handover | Use

#### Synergies with other credits

* Energy Use
* Upfront Carbon Emissions
* Water Use
* Other Carbon Emissions
* Responsible Products

#### Sustainable Development Goals

* **Goal 12:**  Responsible Consumption and Production
* **Goal 13:** Climate Action

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Credit Achievement</mark>

The project must comply with the following criteria:

* Life Cycle Assessment

#### 26.1.1 Life Cycle Assessment

The reduction in life cycle impacts must be demonstrated through a whole-of-building, whole-of-life (cradle to grave) comparative Life Cycle Assessment (LCA), as defined by EN 15978. All EN 15978 modules (A to D) must be included in the assessment.

The results of the LCA must be entered into the GBCA's *Life Cycle Assessment calculator*, which will apply normalisation and weightings to the results to determine compliance with the credit. Results are to be reported in the functional unit of per square metre of Gross Floor Area (GFA).

The reduction must be against the impact categories below:

<table data-search="false"><thead><tr><th width="225">Impact category</th><th>Unit</th><th width="135">Normalisation factor</th><th>Weighting factor</th></tr></thead><tbody><tr><td>Climate change</td><td>kg CO₂ equivalents (GWP100)</td><td>6.96E+03</td><td>25.0%</td></tr><tr><td>Net use of fresh water</td><td>m³</td><td>2.67E+02</td><td>25.0%</td></tr><tr><td>Stratospheric ozone depletion potential</td><td>kg CFC 11 equivalents</td><td>4.75E-02</td><td>0%</td></tr><tr><td>Acidification potential of land and water</td><td>kg SO₂ equivalents</td><td>3.87E+01</td><td>10%</td></tr><tr><td>Eutrophication potential</td><td>kg PO₄ equivalents</td><td>1.37E+01</td><td>10%</td></tr><tr><td>Photochemical Ozone Creation Potential</td><td>Kg C₂H₄ equivalents</td><td>3.44E+00</td><td>10%</td></tr><tr><td>Mineral depletion (Abiotic Depleting Potential)</td><td>kg Sb equivalents</td><td>6.27E-02</td><td>10%</td></tr><tr><td>Fossil fuel depletion (Abiotic Depletion Potential)</td><td>MJ net calorific value</td><td>1.47E+06</td><td>10%</td></tr></tbody></table>

The *Credit Achievement* cannot be claimed if the calculated impact in any one category (after normalization and weighting) is worse than -10%.

For all building types, a standard practice reference building as per EN 15978 must be used. The reference building must be a standard practice, code-compliant design, which is fit-for-purpose for the site and operating conditions of the proposed building.

#### *Methodology*

**Scope**\
Whole-of-Building as defined in EN 15978. Refer to section 7.5 'The Building Model'.

**System boundary**\
Cradle to grave, including all life cycle modules (modules A to D) and scenarios as detailed in EN 15978.

**Functional unit**\
Impacts are assessed and reported on a per square metre (m²) project Gross Floor Area (GFA) basis.

**Service life of permanent building elements**\
The service life required by the client or through regulations, whichever is the greater. If no required service life is defined, a default service life of 60 years is to be applied.

**Service life of replaceable building and construction elements**\
Use actual product/material design life or refer to table 9: Indicative component lifespan of RICS professional standards and guidance, UK Whole life carbon assessment for the built environment (2017).

#### *LCA Data*

The selection of data must be based on EN 15978 for construction materials. Data quality shall be reported and peer reviewed.

Use of locally based data, preferably EN15804 compliant Environmental Product Declarations (EPDs), shall take precedence over generic or global data, where available unless it is for imported products.

The standard for non-construction product EPDs is ISO 14025.

#### *Quality Assurance*

The LCA report must comply with quality assurance requirements by meeting one of two options:

**Option A**

* The report produced by an LCA Certified Practitioner
* Subject to organisational quality assurance, which has been certified in accordance with ISO9001.

**Option B**

* The report produced by an Experienced Individual
* Peer reviewed by an LCA Certified Practitioner or independent Experienced Individual

Refer to the *Definitions* section for competency requirements.

***

## <mark style="color:$primary;">Alternative pathways</mark>&#x20;

Where there are alternative pathways that a project can follow to achieve the credit, or sector specific alternatives.&#x20;

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Alternative pathways</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Clarifications</mark>

Where GBCA have clarified any requirements of the credit criteria. This information is additional and it is not complusory to apply.

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Clarifications</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Submission content</mark>

#### Submissions for this credit must contain:

* **Submission form** through Green Star Online
* **Life Cycle Impacts calculator**
* **Evidence** to support claims made in the submission

#### Recommended evidence:

* LCA Report
* Peer Review Statement
* LCA practitioner competencies statement or LCACP certificate for practitioner and peer reviewer
* Reference building documentation
* Proposed building documentation

Alternate documentation can also be used by project teams to demonstrate compliance.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

The key requirement is that evidence is provided to support each claim made within the Submission form.

***

## <mark style="color:$primary;">Guidance</mark>

**Upfront Carbon Emissions credit**\
The results from this credit can be used to demonstrate compliance with the Upfront Carbon Emissions credit.

**LCA data**\
When conducting the LCA for the project, the following Green Star based inputs shall be consistent with:

* Reference Building operational energy benchmarks as used in the Energy Use calculator for the project for year one energy use
* Reference Building Water usage as used in the Water Use credit (if targeted)
* Product-specific and industry-wide EPDs submitted in response to the Responsible Products credits (if targeted)

**Bio-based materials**\
For purposes of the reduction calculation in Upfront Carbon Emissions, products that have a Global Warming Potential Total (GWPT) of less than zero must use a GWPT of zero.

In other words, should a product have a negative Global Warming Potential Biogenic (GWPB) that exceeds the Global Warming Potential Fossil (GWPF), that product can be assumed to have no carbon, but cannot be used to reduce the carbon for another product or other modules.

In all Life Cycle Impacts calculations, GWPB must be reported separately, but can be taken into account in the final whole of life calculation. GWPB can only be taken into account when the calculation includes the end of life stage, and the timber has an FSC, Responsible Wood, or PEFC chain of custody.

**Emission factors for electricity use**\
If the building has a design life of 60 years or more, future energy projections assuming decarbonisation of the power supply may be calculated using current state/territory emissions factors and dividing by four.

The division by four assumes a linear taper of grid emissions to zero carbon over the first 30 years (divide by two) and then continuing zero carbon emissions for the following 30 years (divide by two again).

The same emissions factor is to be applied across the whole life span of the building. If the Energy Source credit is targeted, the emissions factor for the sourced electricity may be applied for the secured contract duration. At the end of the contract and for the remaining lifespan of the building, the standard emissions factor is to be applied.

If the design life of the building is shorter, future energy projections must be calculated for both the reference and actual LCA models in accordance with RICS (2017) Section 3.4.2 Future energy projections – Decarbonisation of the energy supply.

**Effects of the Zero Carbon Action Plan**\
The effects of the Zero Carbon Action Plan cannot be taken into account in the LCA model.

**Reference building**\
The reference building is a hypothetical building that represents standard contemporary construction and operation practices. The reference building shall be agreed through consultation with structural, mechanical, electrical, and architectural professionals.

The reference building and the proposed project building must have the same:

* Structural requirements
* Scale
* Function
* Location
* Tenant requirements
* Aesthetics
* Site conditions including underlying geology
* Planning constraints
* Orientation
* Season of construction

The reference building is to be defined using conventional materials predominant for the building and deemed to satisfy current National Construction Codes (NCC), as detailed in the NCC Volume 1 Building Code of Australia. Building fabric must be compliant with NCC V1 Section J Deemed-to-Satisfy (DTS) requirements.

Modelled energy consumption of the standard practice reference building shall be based on NCC V1 Section J DTS compliance. Maximum permissible lighting levels in line with NCC shall be used. Heating and cooling appliances must comply with efficiencies which meet the latest Minimum Energy Performance Standards (MEPS) and where relevant Section J DTS requirements.

***

## <mark style="color:$primary;">Definitions</mark>

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#commissioner)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#lca-certified-practitioner)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#lca-experienced-individual)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#lca-peer-review)

***

## <mark style="color:$primary;">Supporting information</mark>

The following resources support this credit:

* EN 15804 Sustainability of Construction Work - Environmental Product Declarations - Core Rules for the Category of Construction Products
* EN 15978 Sustainability of Construction Works – Assessment of environmental performance of buildings - Calculation method
* RICS professional standards and guidance, UK Whole life carbon assessment for the built environment (2017)
* ISO 14025 Environmental labels and declarations - Type III environmental declarations - Principles and procedures


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/positive/26-or-life-cycle-impacts.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.