> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/sector-specific-credits/upfront-fitout-emissions.md).

# Upfront Fitout Emissions

Points: 3

{% hint style="info" %}
**Sector Specific credit**\
**Applicability:** Buildings where more than 20% of GFA is commercially leased to tenants, e.g. office, retail, industrial.
{% endhint %}

## <mark style="color:$primary;">Outcome</mark>

The building owner drives tenants to eliminate their upfront carbon emissions.

## <mark style="color:$primary;">Criteria</mark>

<mark style="color:$success;">**Credit Achievement — 1 point**</mark>

* The building owner actively assists the tenants to quantify and reduce their upfront carbon emissions from fitouts
* Fitout upfront carbon emissions for at least 10% of tenanted space (by NLA) has been quantified and fully offset
* The building owner requires tenants to use low GWP refrigerants or offsets for high GWP refrigerant leakage are procured

<mark style="color:$success;">**Exceptional Performance — 2 points**</mark>

* Fitout upfront carbon emissions for at least 40% of tenanted space (by NLA) has been quantified and fully offset

***

## <mark style="color:$primary;">Additional information</mark>

#### **Stage implemented**

**Strategy** | **Brief** | **Concept** | **Design** | **Tender** | **Construction** | **Handover** | **Use**

#### Synergies with other credits

* Upfront Carbon Emissions
* Life Cycle Impacts
* Climate Change Resilience

#### Sustainable Development Goals

* **Goal 7:** Affordable and Clean Energy
* **Goal 13:** Climate Action

#### Relevant reporting initiatives

* GRESB
* Task Force on Climate-related Financial Disclosures **(TCFD)**

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Credit Achievement</mark>

The project must comply with **both** of the following criteria:

* Upfront Carbon
* Refrigerants

#### Upfront Carbon

The building owner provides a mechanism for tenants to address their upfront carbon emissions by recognising and reducing emissions and compensating remaining emissions through the purchase of appropriate offsets. The mechanism used must also allow the building owner to collect information from the tenant related to their upfront emissions.

#### *Quantifying emissions*

Upfront tenant emissions must be quantified. Emissions must be captured in kg CO2eq.

Tenant upfront carbon emissions are the emissions from the manufacturing, transport, and installation of all fitout related items. This includes furniture, tenant installed supplementary systems, finishes and fittings. Items installed by the building owner are covered under *Upfront Carbon Emissions* in the Positive category.

#### *Offsets*

The purchased offsets must be from afforestation and reforestation activities, or domestic renewable energy generation. Refer Appendix B of the guide 'Climate Positive Buildings and our Net Zero Ambitions' published by GBCA for eligible offsets

#### *Engagement activities*

The building owner actively encourages the tenants to reduce and compensate for their upfront carbon emissions from their fitouts, and all emissions from refrigerants through an engagement campaign with tenants. This can be via programs related to the building (websites, brochures, emails, meetings, etc).

#### *Engaged tenants*

At least 10% of tenant space (NLA) must be signed up to reduce and compensate fitout upfront carbon emissions to demonstrate the program is operational. Tenants must have fully offset their upfront emissions or signed up to a mechanism that guarantees these emissions will be fully offset. In addition to the above, the building owner and the tenant must agree to share data regarding the base building upfront carbon.

#### Refrigerants

The building owner must address all tenant refrigerant emissions by **either**:

* Eliminating Refrigerants
* Offsetting Refrigerants

A combination of these two options may be used.

#### *Eliminating refrigerants*

The building owner must have requirements for tenants that high-GWP refrigerants must be eliminated from the building. The use of refrigerants with a GWP of 10 or less is considered to comply with the credit. Natural refrigerants in most cases comply with this criterion.

#### *Offsetting Refrigerants*

100% of carbon emissions from high GWP refrigerants (GWP > 10) must be offset.

Carbon emissions are calculated by multiplying the initial refrigerant charge by its Global Warming Potential (GWP) for each type of refrigerant present in the building and adding the emissions together.

See Appendix B of the GBCA's Climate positive buildings and our net zero ambitions document available from Green Star resources for more information on acceptable offsets.

### <mark style="color:$success;">Exceptional Performance</mark>

The project must comply with the following criteria:

* Tenant Engagement

#### Tenant Engagement

Fitout upfront carbon emissions for 40% of tenanted space by NLA has been measured and fully offset.

Requirements for Quantifying Emissions and Offsets as per Upfront Carbon in the Credit Achievement.

***

## <mark style="color:$primary;">Guidance</mark>

Guidance is supporting information for the credit requirements and is not mandatory to apply.

**Applicability**\
This credit applies to all commercial buildings where more than 20% of the area of the building is tenanted to entities that are separate to the building owner or operator (e.g. hotel operator). For buildings where there is no or little tenanted space, or where the building owner retains operational control over most spaces, those emissions from energy would be covered under Upfront Carbon Emissions.

**Emissions boundary**\
Manufacturing, specialised equipment (such as an MRI machine) and plug-in equipment (e.g. IT and appliances) are excluded from this credit.

**Calculating emissions**\
Upfront carbon emissions are defined as those calculated for the Global Warming Impact Category in line with EN15978 in modules A1 to A5. Where the credit 'Life Cycle Impacts is being claimed, and the LCA boundary includes the fitout, the information from those modules can be used to calculate the emissions for this credit.

If a detailed embodied carbon assessment is not undertaken, then a fitout value of 250 kgCO2 per m² of NLA can be assumed. This excludes carpets and ceilings" GBCA will provide further guidance on benchmarks in future.

**Mechanisms for tenant offsetting**\
Mechanisms that can be used include clauses in standard lease agreements, introduction of levies or incentives, programs made available through tenant portals, any other similar mechanism that allows the building owner to encourage tenants to calculate and offset upfront fitout emissions.

**Upfront Carbon reduction**\
Building owners are encouraged to outline the benefits of reducing tenant upfront emissions as a first principle. This could help reduce the number of offsets purchased to meet credit requirements.

***

## <mark style="color:$primary;">Submission content</mark>

#### Submissions for this credit must contain:

* Submission Summary via the online portal
* Evidence to support claims made in the submission

#### Recommended evidence

* Evidence of the mechanism used to encourage tenants to address their upfront emissions (contracts, incentive documents, portal screenshots, etc)
* Communications material to show intent to encourage tenants to address their emissions
* Extracts from the agreements showing that data will be shared between building owner and tenants
* Summary of tenants in the building, confirmation of which tenants have or are offsetting
* Leasing clauses requiring low GWP refrigerant use or purchased offsets to cover high GWP refrigerant use

***

## <mark style="color:$primary;">Supporting information</mark>

The following resources support this credit:

* Climate positive buildings and our net zero ambitions
* GBCA's Climate Positive Roadmap
* WorldGBC's Net Zero Carbon Buildings Commitment


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/categories-and-credits/sector-specific-credits/upfront-fitout-emissions.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.