> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/healthy-3/12-or-light-quality.md).

# 12 | Light Quality

Points: 4

## <mark style="color:$primary;">Outcome</mark>

The building provides good daylight and its lighting is of high quality.

## <mark style="color:$primary;">Criteria</mark>

<mark style="color:$success;">**Minimum Expectation — Nil**</mark>

* [#id-12.0.1-lighting-comfort](#id-12.0.1-lighting-comfort "mention")**:** Lighting within the building meets minimum comfort requirements.
* [#id-12.0.2-glare-from-light-sources](#id-12.0.2-glare-from-light-sources "mention")**:** Good lighting levels suitable for the typical tasks in each space are available.
* [#id-12.0.3-daylight-strategy](#id-12.0.3-daylight-strategy "mention")**:** The building aims to maximise access to daylight.

<mark style="color:$success;">**Credit Achievement — 2 points**</mark>

In addition to *Minimum Expectation*:

* [#id-12.1.1-artificial-lighting](#id-12.1.1-artificial-lighting "mention")**:** The building provides best practice artificial lighting.

or

* [#id-12.1.2-daylight](#id-12.1.2-daylight "mention")**:** The building provides best practice access to daylight.

<mark style="color:$success;">**Exceptional Performance — 2 points**</mark>

In conjunction with *Credit Achievement*, the project meets **both** of the following

* [#id-12.2.1-artificial-lighting](#id-12.2.1-artificial-lighting "mention")**:** The building provides best practice artificial lighting.
* [#id-12.2.2-daylight](#id-12.2.2-daylight "mention")**:** The building provides best practice access to daylight.

***

## <mark style="color:$primary;">Additional information</mark>

#### Scope of credit

Lighting being delivered in the regularly occupied, internal and unenclosed covered areas of the building. Spaces can be excluded with confirmation via a Technical Question if the use of the space justifies specific lighting conditions. Refer Guidance for examples.

Emergency lighting, decorative light fixtures and landscaping fixtures are excluded if it is not a primary source of lighting.

#### Stage implementation

Strategy | Brief | **Concept** | **Design** | **Tender** | Construction | Handover | Use

#### Synergies with other credits

* Amenity and Comfort
* Verification and Handover

#### Sustainable Development Goals

* **Goal 3:** Good Health and Wellbeing

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Minimum Expectation</mark>

The project must comply with **all three** of the following criteria:

* Lighting Comfort
* Glare from Light Sources
* Daylight Strategy

#### 12.0.1 Lighting Comfort

The lighting within 95% of the regularly occupied, fully enclosed covered areas and unenclosed covered areas in the project boundary meets one of the following pathways based on the building class space type delivered. Mixed use projects, where more than 20% of the GFA, excluding car parks, is not the predominant building type, may be required to comply with more than one pathway.

<table><thead><tr><th>Criteria</th><th>Class 2, 3 and 9c requirements</th><th>High bay lighting in Class 7b and 8 requirements</th><th>All other building classes</th></tr></thead><tbody><tr><td>Colour Rendering Index</td><td>Min of 85</td><td>Min of 80</td><td>Min of 85</td></tr><tr><td>MacAdam Ellipses or a Standard Deviation Colour Matching</td><td>3 or lower</td><td>5 or lower</td><td>3 or lower</td></tr><tr><td>Flicker free</td><td colspan="3"><p>'Low Risk" or "No Observable Effect" in accordance with <em>IEEE 1789-2015 Recommended Practices for Modulating Current in High-Brightness LEDs for Mitigating Health Risks to Viewers.</em></p><p><br>or</p><p><br>A PstLM ≤1.0 measured according to <em>IEC TR 61547-1</em> and a Stroboscopic Visibility Measure (SVM) ≤ 0.4.</p></td></tr><tr><td>Uniformity</td><td>Nil</td><td colspan="2">A uniformity of no less than that specified in Table 3.2 of <em>AS/NZS 1680.1:2006</em>, with a maintenance factor method as defined in <em>AS/NZS 1680.4</em>.</td></tr></tbody></table>

{% hint style="success" icon="dot" %}
**Fitout scope**\
Where there are fitout works excluded from the rating, the lighting that is installed in the regularly occupied areas complies with the requirements. Lighting requirements for tenant installed lighting are included in a tenancy fitout guide and model lease clauses for tenants.
{% endhint %}

#### 12.0.2 Glare from Light Sources

Glare from light sources is limited in 95% of the regularly occupied areas. Project teams may choose at least one of the following pathways. A combination of methods can be used to demonstrate compliance to suit different spaces.

<table><thead><tr><th width="168.25">Pathway</th><th>Requirements</th></tr></thead><tbody><tr><td>Prescriptive method 1</td><td>Bare light sources are fitted with baffles, louvers, translucent diffusers, ceiling design, or other means that obscures the direct light source from all viewing angles of occupants, including occupants looking directly upwards.</td></tr><tr><td>Prescriptive method 2</td><td>Where the nature of the tasks, layout, and surface reflectance in a space are not known (e.g., shell and core) the lighting system complies with the Luminaire selection system as detailed in Clause 8.3.4 of <em>AS/NZS 1680.1:2006.</em></td></tr><tr><td>Performance method</td><td>The Unified Glare Rating (UGR) calculated for the lighting on a representative floor does not exceed the maximum values listed in the <em>AS/NZS 1680.2</em> series applicable to the space use or Table 8.2 of <em>AS/NZS 1680.1:2006</em> where the space use is not specifically covered in the <em>AS/NZS 1680.2</em> series.<br><br>The UGR is calculated in accordance with Clause 8.3.3 of <em>AS/NZS 1680.1:2006.</em><br><br>The project team may nominate a grid for the calculation based on the specific requirements of the project.</td></tr></tbody></table>

{% hint style="success" icon="dot" %}
**Fitout scope**\
Where there are fitout works excluded from the rating, the lighting that is installed in the regularly occupied areas complies with the requirements. Glare reduction requirements for tenant installed lighting are included in a tenancy fitout guide and model lease clauses for tenants.
{% endhint %}

#### 12.0.3 Daylight Strategy

A daylight strategy is prepared by the project team. The strategy outlines how the building's design will provide access to daylight beyond regulatory requirements.

As a minimum, the strategy includes:

* A description of how the building's design:
  * Maximises access to daylight in the regularly occupied areas.
  * Controls or mitigates external glare in the daylit spaces.
  * Provides building occupants with unrestricted access to daylit regularly occupied common areas.
* A description of any barriers (if present) to providing access to daylight in all regularly occupied areas and the measures taken to mitigate loss of daylight quality for occupants.
* A simple calculation of the proportion of regularly occupied areas in the building that have access to daylight. Refer to the GBCA's [Daylight and Views calculation guide](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.0-rev-c/calculation-guides/daylight-and-views-calculation-guide.md) on how to calculate this.

Where compliance with the Daylight criterion in *Credit Achievement* is demonstrated, this criterion is deemed to be met.

### <mark style="color:$success;">Credit Achievement</mark>

In addition to *Minimum Expectation*, the project must comply with **one** of the following criteria:

* Artificial Lighting
* Daylight

#### 12.1.1 Artificial Lighting

The artificial lighting in the regularly occupied areas provides high quality light exposure that supports task visibility, visual comfort and well-being. Project teams must choose one of the following pathways relevant to the project's building class space type.

<table><thead><tr><th width="181.5">Pathway</th><th>Requirement</th></tr></thead><tbody><tr><td>Class 2, 3 and 9c</td><td><p>Artificial lighting in 95% of the regularly occupied areas is provided that meets both of the following:</p><ul><li><strong>Task areas including kitchen and study areas</strong>: Horizontal illuminance levels meet or exceed the maintained illuminance levels in relevant <em>AS/NZS 1680.2</em> series for the type of activity at the working plane. Where an activity is not specifically covered, the maintained illuminance values are selected from Table 3.1 in <em>AS/NZs 1680.1</em>. At least 50% of the maintained illuminance value reaches average eye height when performing the task. This is calculated using a vertical illuminance calculation grid.</li><li><strong>Other regularly occupied areas:</strong> Horizontal illuminance levels meet or exceed the maintained illuminance levels for general lighting systems in Table 3.2 in <em>AS/NZS 1680.1</em>. At least 20% of the vertical area of the wall in the field of view is illuminated to create demonstrable contrast and visual interest. The contrast between spaces do not exceed the maximum luminance ratios in Table 3.2 in <em>AS/NZS AS 1680.1</em>.</li></ul></td></tr><tr><td>All other building classes</td><td><p>Artificial lighting in 95% of the regularly occupied areas meets one of the following based on how the space will be used:</p><ul><li><strong>Task areas:</strong> Horizontal illuminance levels meet or exceed the maintained illuminance levels in relevant <em>AS/NZS 1680.2</em> series for the type of activity at the working plane. Where an activity is not specifically covered, the maintained illuminance values are selected from Table 3.1 in <em>AS/NZs 1680.1</em>. At least 50% of the maintained illuminance value reaches average eye height when performing the task. This is calculated using a vertical illuminance calculation grid.</li><li><strong>Other regularly occupied areas</strong>: Horizontal illuminance levels meet or exceed the maintained illuminance levels in relevant <em>AS/NZS 1680.2</em> series for the type of interior at a working plane of 0.85m above floor level.</li></ul><p>In addition, the contrast between spaces do not exceed the maximum luminance ratios in Table 3.2 in <em>AS/NZS AS 1680.1</em>.</p></td></tr></tbody></table>

{% hint style="success" icon="dot" %}
**Fitout scope**\
Compliant lighting is delivered in at least 80% of the GFA, excluding car parks. This includes tenanted spaces.
{% endhint %}

#### 12.1.2 Daylight

#### *Daylight levels*

The building provides access to high levels of daylight. Project teams must choose one of the following pathways relevant to the project's building class space type.

<table><thead><tr><th width="239">Pathway</th><th>Requirement</th></tr></thead><tbody><tr><td>Class 2 and 3</td><td>In at least 95% of units, at least 60% of the combined regularly occupied areas of each unit receives high levels of daylight with at least 20% of each bedroom and living area having high levels of daylight.</td></tr><tr><td>All other building classes</td><td>In at least 95% of the regularly occupied areas of the building, at least 40% of the area receives high levels of daylight with at least 20% of each floor or tenancy (whichever is smaller) having high levels of daylight. Where there are regularly occupied common areas, at least 20% of this area receives high levels of daylight.</td></tr></tbody></table>

#### *Daylight calculation*

Daylight is calculated using Daylight Autonomy, measuring illuminance for at least every hour within the nominated hours. A Daylight Autonomy of at least 160 lux for 80% of the nominated hours is provided to be considered as providing high levels of daylight.

#### *External glare control*

Glare from sunlight through all viewing façades and skylights are reduced in the regularly occupied areas where occupants are expected to be stationary. Refer *Guidance* for examples of excluded spaces.

Project teams must choose from at least one of the following pathways. A combination of methods can be used to demonstrate compliance to suit different spaces.

<table><thead><tr><th width="221.5">Pathway</th><th>Requirement</th></tr></thead><tbody><tr><td>Fixed shading devices</td><td>The nominated plane in 95% of the regularly occupied areas is shaded from direct sunlight for 80% of the nominated hours for each day of the autumn and spring equinoxes and the summer and winter solstices.<br><br>Refer <em>Guidance</em> for further guidance on the nominated plane.</td></tr><tr><td>Blind or screens in Class 2 or 3</td><td><p>At least 95% of the combined area of the viewing facades and skylights have blinds or screens to provide glare reduction with all bedrooms having blackout blinds.</p><p><br>Where the blinds or screens are part of a packaged décor, blackout blinds are offered as standard inclusion which are controlled manually or automatically as per the Blinds or screens in all other building classes pathway.</p><p><br>Where the blinds or screens are not installed by the developer, the window and ceiling design does not obstruct the future installation of blinds or screens. A guide is provided to future occupants on what blinds and screens would be suitable (i.e., provide dimensions, fixing points, fixing types etc.) and appropriate fixing points and mechanisms.</p></td></tr><tr><td>Blinds or screens in all other building classes</td><td><p>At least 95% of the combined area of the viewing facades and skylights have blinds or screens to provide glare reduction. The blinds or screens have a visual light transmittance (VLT) of ≤ 10%.<br>The blinds or screens are controlled by one of the following:</p><ul><li><strong>Manually</strong> by the occupants of the space.</li><li><strong>Automatically</strong> by a centralised management system or activated by a switch. If centralised, a manual override function is available to the occupants in each of the adjacent spaces served.</li></ul></td></tr><tr><td>Performance method</td><td>A combination of tinted glazing, fixed shading devices and other solutions is demonstrated via modelling to provide a reduction of glare equivalent to that provided by one of the above pathways.</td></tr></tbody></table>

### <mark style="color:$success;">Exceptional Performance</mark>

In conjunction with *Credit Achievement*, the project must comply with **both** of the following criteria:

* Artificial Lighting
* Daylight

#### 12.2.1 Artificial Lighting

Refer *Credit Achievement* for requirements.

#### 12.2.2 Daylight

Refer *Credit Achievement* for requirements.

***

## <mark style="color:$primary;">Alternative pathways</mark>&#x20;

Where there are alternative pathways that a project can follow to achieve the credit, or sector specific alternatives.&#x20;

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Alternative pathways</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Clarifications</mark>

Where GBCA have clarified any requirements of the credit criteria. This information is additional and it is not complusory to apply.

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Clarifications</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Definitions</mark>

Definitions provided here must be applied to Requirements unless agreed with GBCA via a Technical Question.

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#decorative-lighting-fixtures)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#field-of-view)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#nominated-hours)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#nominated-plane)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#regularly-occupied-area)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#task-areas)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#working-plane)

***

## <mark style="color:$primary;">Guidance</mark>

Guidance is supporting information for the credit requirements and is not mandatory to apply.

**Daylight strategy**\
As adequate daylight promotes improved productivity and wellbeing, buildings that have spaces that prioritise learning, healing and living are encouraged to maximise daylight in these spaces. This includes classrooms in schools, patient rooms in hospitals and living and bedroom areas in apartments.

**Wall in the field of view**\
This is any wall that is visible from where the occupant is expected to be working or utilising the space. Joinery, doors or glazing installed at the time of submission are not included in the vertical area of the wall.

**Calculating Daylight Autonomy**\
There are a number of dynamic simulation software programs that are available to calculate Daylight Autonomy including, but not limited to, IESVE Radiance, Daysim, ESP-r, Lightswitch Wizard, and SPOT (>Ver 4.0). Where other programs are used, the project team demonstrates that the software is based on the Radiance simulation engine, and that it uses the statistical sky, the daylight coefficients and Perez All Weather Sky model, or the annual CIE sky simulation algorithms.

**Excluded spaces**\
Below are some examples of spaces that can be typically excluded for different criteria. If the project has other types of spaces where the function justifies specific lighting conditions, a Technical Question may be submitted to the GBCA for confirmation to be excluded.

*Daylight levels*\
Example of spaces that can be excluded include spaces that require a high degree of privacy, operating rooms and spaces that require controlled lighting for performances or projection such as theatres and cinemas.

For Class 2 and 3 spaces, bathroom and kitchen areas can be excluded. Where there are no physical barriers around the kitchen and adjacent rooms, the excluded area is a 1.5m band from the wall behind the counter.

*External glare control*\
Example of spaces that can be excluded include, but are not limited to, retail spaces, supermarket floors, logistics warehouse areas and office lobbies however it is noted that glare control is to be provided to screen-based task areas such as the check out or occupied reception desks.

***

## <mark style="color:$primary;">Submission content</mark>

Submissions for this credit must contain:

* **Submission form** through Green Star Online
* **Evidence** to support claims made in the submission

#### **Recommended evidence**

The following list of evidence serves as a guide for the Certified submission and is not exhaustive. Project teams are not required to provide all of the listed items and alternate forms of documentation can be used to demonstrate compliance. The key requirement is that evidence is provided to support each claim.

* Daylight modelling report or manual calculations.
* Lighting Drawings.
* Architectural Drawings.
* Lighting Specifications/Schedules.
* Product Data Sheets.
* Isolux Plot Drawings.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

***

## <mark style="color:$primary;">Supporting information</mark>

The following resources support this credit:

* AS1680 series – Interior and workplace lighting
* AS/NZS1158
* IEEE 1789-2015 - IEEE Recommended Practices for Modulating Current in High-Brightness LEDs for Mitigating Health Risks to Viewers
* Better Building Partnership Green Leasing: <https://www.betterbuildingspartnership.com.au/projects/green-leasing/>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/healthy-3/12-or-light-quality.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.