> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/places-2/30-or-movement-and-place.md).

# 30 | Movement and Place

Points: 3

## <mark style="color:$primary;">Outcome</mark>

The building's design and location encourage occupants and visitors to use active and public transport options instead of private vehicles.

## <mark style="color:$primary;">Criteria</mark>

<mark style="color:$success;">**Minimum Expectation — Nil**</mark>

* [#id-30.0.1-changing-facilities](#id-30.0.1-changing-facilities "mention"): The building includes showers and changing facilities for building occupants.
* [#id-30.0.2-safe-ingress](#id-30.0.2-safe-ingress "mention"): Access to changing facilities is safe and protected.

<mark style="color:$success;">**Credit Achievement — 2 points**</mark>

In addition to *Minimum Expectation*:

* [#id-30.1.1-sustainable-transport](#id-30.1.1-sustainable-transport "mention"): A Sustainable Transport Plan has been prepared and implemented to encourage active transport and reduce private vehicle usage.
* [#id-30.1.2-active-transport-facilities](#id-30.1.2-active-transport-facilities "mention"): The building has facilities to support the use of active transport.
* [#id-30.1.3-encouraging-walkability](#id-30.1.3-encouraging-walkability "mention"): The building's design and location encourage walking.

***

## <mark style="color:$primary;">Additional information</mark>

#### Scope of credit

All regular occupants (e.g., staff, residents) and visitors.

**Changing Facilities**

The number of facilities provided are based on the number of users that would be regularly occupying the building, not including visitors and residents. This means the following:

* Residents in Class 2 and 4 spaces are excluded.
* Only staff in Class 3 and 9 spaces are included. Short or long-term residents, visitors and patients are excluded.
* Only regular occupants in Class 5, 6, 7b and 8. Visitors are excluded.

#### Stage implementation

**Strategy** | **Brief** | **Concept** | **Design** | **Tender** | **Construction** | Handover | Use

#### Synergies with other credits

* Community Resilience
* Low-Emissions Transport

#### Sustainable Development Goals

* **Goal 3:** Good Health and Wellbeing
* **Goal 11:** Sustainable Cities

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Minimum Expectation</mark>

The project must comply with **both** of the following criteria:

* Changing Facilities
* Safe Ingress

#### 30.0.1 Changing Facilities

#### *Showers*

The building provides showers based on the design occupancy of the building:

| Occupants | Showers                                  |
| --------- | ---------------------------------------- |
| 0 - 49    | 1 Unisex                                 |
| 50-99     | 2                                        |
| 100 - 200 | 4                                        |
| 200+      | Additional 1 per 200 occupants above 200 |

A pro-rata approach to calculating the number of showers required for the number of regular building occupants can be taken.

All showers are at least 900 mm x 900 mm to enhance usability. Showers and bathrooms provided to meet statutory accessibility requirements, or showers provided in statutorily required facilities (e.g., adult changing facilities) do not count towards the minimum showers required to meet this criterion.

#### *Lockers*

One locker is provided for every eight occupants based on the design occupancy. The lockers are secure and located within the end-of-trip facilities.

Lockers provided within tenancies, not in or near changing rooms, do not count toward this credit.

{% hint style="success" icon="dot" %}
**Mixed use buildings with tenants**\
Mixed use buildings that made up of a majority of Class 2 and Class 3 student accommodation spaces are exempt from providing changing facilities for retail and office where the total amount of retail and/or office tenancy is less than 1% of the building's GFA, excluding car parks, or less than 200m2.
{% endhint %}

#### 30.0.2 Safe Ingress

Access from the site boundary and between buildings to the changing facilities is safe and protected by providing users with the following:

* A separate or distinct access path from the vehicle ingress/entries;
* Access that is free from steep gradients and has appropriate surface grip; and
* Clear signed across the site.

The changing facilities street level entry is well-lit, clearly signed and has an awning that provides users protection from the elements.

The changing facilities have lighting in accordance with *AS/NZS 1680.2.1:2008 Interior and workplace lighting, Part 2.1: Specific applications – Circulation spaces and other general areas.*

### <mark style="color:$success;">Credit Achievement</mark>

In addition to *Minimum Expectation*, the project must comply with all **three** of the following criteria:

* Sustainable Transport
* Active Transport Facilities
* Encouraging Walkability

#### 30.1.1 Sustainable Transport

A Sustainable Transport Plan is prepared by a suitably qualified transport planner or engineer. Requirements or recommendations made in the Sustainable Transport Plan are reflected in the design of the building's facilities and ongoing operational processes.

As a minimum, the Sustainable Transport Plan includes:

* A definition of the typical mode share of the development location and development type.
* A target mode share for the development that prioritises active and public transport modes, and recommendations on how to achieve them.
* Outline of how other modes of transport (carpooling, electric vehicles, and drop-off points) will be encouraged over private vehicle use.
* Identification of future infrastructure projects (such as bike lanes, precinct development, new transport services etc) which may change or influence mode share (such as planned, or under construction infrastructure) and the year of completion for the new infrastructure.
* Roles and responsibilities for implementing, monitoring, and auditing the Sustainable Transport Plan in the building's operational phase.

#### *Reducing Private Vehicle Use*

The Sustainable Transport Plan encourages active transport and reduces private vehicle kilometres travelled when compared to a reference building by demonstrating:

* Active mode encouragement: 90%
* Vehicle Kilometres Travelled (VKT) reduction: 20%

This is demonstrated by completing the *Movement and Place calculator.*

#### 30.1.2 Active Transport Facilities

#### *Bicycle parking*

The project provides bicycle parking where the amount of parking is informed by the Sustainable Transport Plan.

At a minimum, the bicycle parking is designed in accordance with Table 1.1 from *AS 2890.3:2015 Parking facilities, Part 3: Bicycle parking*.

Access to and entry to bike parking meets the [*Safe Ingress*](#id-30.0.2-safe-ingress) requirements in *Minimum Expectation*.

#### *Personal Electric Vehicles (PEVs) parking*

Parking for PEVs (e.g., electric bikes, electric scooters) is provided. The amount of parking is determined by the Sustainable Transport Plan. Projects may choose one of the pathways relevant to the project's building type.

<table><thead><tr><th width="172.75">Pathways</th><th>Requirements</th></tr></thead><tbody><tr><td>Class 2</td><td><p>The building provides:</p><ul><li>1 charging point per 10 PEV parking spaces. This may be in the form of an easily accessible power point.</li><li>All designated PEV parking spaces are in a room that has controlled access such as an occupant access card or similar. The room has opaque walls or wall coverings and is accessible via a wide, non-swinging door (unless automatic). Parking spaces in the secure room accommodate a range of PEV sizes and weights.</li></ul></td></tr><tr><td>Class 5 or 6</td><td><p>The building provides:</p><ul><li> 1 charging point per 4 electric PEV parking spaces, or 1 point per 10 regular bike parking spaces. This may be in the form of an easily accessible power point.</li><li>A designated PEV parking area that is located close to the entrance of the building or within a secure bike parking facility. The parking spaces are to allow both front and back wheels to be secured, is wide enough to accommodate all bike sizes and do not require lifting.</li><li>A ramp of a maximum gradient of 1:14 or non-ramped access to the PEV parking area. Wheel tracks or ramps down the side of a set of stairs are not acceptable as ramped access.</li></ul></td></tr></tbody></table>

#### 30.1.3 Encouraging Walkability

#### *Roads*

Roads within the site boundary prioritises pedestrians over vehicles and have a maximum speed of 10km/hr. Pedestrians and/or active transport have right of way.

#### *Amenity diversity*

Occupants have access to a diversity of amenities by having at least 10 amenities across five categories within 400m of the building ⓘ[^1] Refer *Guidance* for the categories of amenities.

***

## <mark style="color:$primary;">Alternative pathways</mark>&#x20;

Where there are alternative pathways that a project can follow to achieve the credit, or sector specific alternatives.&#x20;

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Alternative pathways</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Clarifications</mark>

Where GBCA have clarified any requirements of the credit criteria. This information is additional and it is not complusory to apply.

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Clarifications</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Definitions</mark>

Definitions provided here must be applied to Requirements unless agreed with GBCA via a Technical Question.

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#default-occupancy)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#design-occupancy)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#qualified-transport-planner)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#reference-project)

***

## <mark style="color:$primary;">Guidance</mark>

Guidance is supporting information for the credit requirements and is not mandatory to apply.

**Location of changing facilities**\
Facilities (including showers, changing rooms and lockers) may be provided in a neighbouring building, within a 5 min walk to the Green Star rated project. The number of facilities in the neighbouring building must cater for the combined building population of the Green Star rated project, and any other neighbouring buildings that rely on the same facilities. The neighbouring building is not required to be targeting or certified to a Green Star rating, however the facilities must be under full or partial operational control of the building owner/management of the project seeking a rating. Clear signage must be provided and access to the facilities, and project occupants are to be made aware of changing facilities in the neighbouring building at the point of onboarding or equivalent.

**Changing facilities**\
The design of the shower facilities must be appropriate to encourage their use. The building should consider features such as ironing boards, iron, hanging racks, power points, mirrors, facial lighting, and any other facilities to encourage uptake. The project team is expected to justify how their location, locker sizes, privacy requirements, and size meet this aim.

Showers may be unisex or can be assigned for gender provided NCC provisions are met.

All-gender facilities can be included in the total where provided.

**Location of bike parking/storage**\
Bike parking/storage does not have to be located on the same floor/area as the changing facilities but must be within easy access of the bike storage. Some examples of what can be accepted:

<table><thead><tr><th width="317.75">Acceptable</th><th width="440.25">Not Acceptable</th></tr></thead><tbody><tr><td><ul><li>Dedicated end-of-trip facilities on another floor, easily accessible by a short walk (not through high traffic areas) or elevator.</li><li>Dedicated end-of-trip facilities located outside of the building but within easy access (e.g., one end-of trip facility for a complex of buildings).</li><li>Lockers provided within end-of-trip facilities</li></ul></td><td><ul><li>Shower facilities on another floor or within tenancies, with access to them through high traffic areas, past tenancies or though main part of building where lots of people are expected to be working, visiting or living.</li><li>Showers provided within other bathrooms that are there to meet statutory accessibility requirements.</li><li>Use of communal showers within a hotel/hostel environment, that customers and occupants use.</li><li>Lockers provided far away from changing facilities.</li></ul></td></tr></tbody></table>

**Amenity categories**\
The categories of amenities include:

* Grocery: e.g., Convenience stores, supermarkets
* Health and wellbeing e.g., dentist, doctor, psychologist
* Food and Beverage: e.g., cafes, restaurants, bars
* Retail: e.g., clothing, homeware, hardware, book, gift stores
* Bank Services: e.g., banks, credit unions, ATMs
* Education and Childcare: e.g., Primary, secondary, tertiary, or childcare facilities
* Recreation: e.g., movie theatres, fitness centres, swimming pools
* Public facilities: e.g., Libraries, local or state government service centres, post office
* Outdoor facilities: e.g., Playgrounds, parks

***

## <mark style="color:$primary;">Submission content</mark>

Submissions for this credit must contain:

* **Submission form** through Green Star Online
* **Evidence** to support claims made in the submission

#### Recommended evidence

The following list of evidence serves as a guide for the Certified submission and is not exhaustive. Project teams are not required to provide all of the listed items and alternate forms of documentation can be used to demonstrate compliance. The key requirement is that evidence is provided to support each claim.

**Changing Facilities**

* Evidence of design occupancy.
* As built drawings highlighting location and size of showers and lockers.

**Safe Ingress**

* Photos and/or as built drawings highlighting the relevant building attributes to demonstrate the changing facilities are safe to access.

**Sustainable Transport Plan**

* Extracts from Sustainable Transport Plan.
* Credentials of suitably qualified transport planner or engineer.
* Movement and Place calculator

**Active Transport Facilities**

* As built drawings highlighting location of bicycle parking and PEV parking.
* As built drawings and product data sheets of bicycle parking.
* Photos and/or as built drawings highlighting the relevant building attributes to demonstrate the bicycle parking is safe to access.
* Photos and/or as built drawings highlighting the PEV parking spaces have the required attributes.

**Encouraging Walkability**

* Photos and/or as built drawings highlighting road signage and markings.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

***

## <mark style="color:$primary;">Supporting information</mark>

The following resources support this credit:

* AS 2890.3:2015 – Parking facilities – Part 3: Bicycle parking
* AS/NZS 1680.2.1:2008 – Interior and workplace lighting – Part 2.1 Specific applications – Circulation spaces and other general areas
* GBCA - [Movement and Place calculation guide](broken://pages/Hb3i8JS6SqAlUXtiaXsW)

[^1]: **18/11/2026**

    Correction: *as determined by the Movement and Place calculator* removed


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/places-2/30-or-movement-and-place.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.