> For the complete documentation index, see [llms.txt](https://greenstarresources.gbca.au/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/positive-3/24-or-upfront-carbon-reduction.md).

# 24 | Upfront Carbon Reduction

Points: 6

## <mark style="color:$primary;">Outcome</mark>

The building's upfront carbon emissions have been reduced.

### <mark style="color:$primary;">Climate Positive Pathway</mark>

<table data-search="false"><thead><tr><th width="329">Registration</th><th width="120.25">Star rating</th><th>Requirement</th></tr></thead><tbody><tr><td rowspan="3">Registering from 2025 onwards</td><td>4 Star</td><td rowspan="2">Meets <em>Minimum Expectation</em></td></tr><tr><td>5 Star</td></tr><tr><td>6 Star</td><td>Meets requirement for all points in <em>Credit Achievement</em></td></tr><tr><td rowspan="3">Registering from 2028 onwards</td><td>4 Star</td><td>Meets <em>Minimum Expectation</em></td></tr><tr><td>5 Star</td><td>Meets requirement for all points in <em>Credit Achievement</em></td></tr><tr><td>6 Star</td><td>Meets requirement for all points in <em>Exceptional Performance</em></td></tr><tr><td rowspan="3">Registering from 2030 onwards</td><td>4 Star</td><td>Meets requirement for all points in <em>Credit Achievement</em></td></tr><tr><td>5 Star</td><td rowspan="2">Meets requirement for all points in <em>Exceptional Performance</em></td></tr><tr><td>6 Star</td></tr></tbody></table>

## <mark style="color:$primary;">Pathways</mark>

There are two pathways available for this credit. Project teams can choose from one of the following:

* Pathway A: Benchmark pathway – Available for Class 2 apartments, Class 5 commercial and Class 7b or 8 industrial only.
* Pathway B: Reference building pathway
* Pathway C: NABERS Embodied Carbon pathway – **In development**; refer to note below.

Mixed use projects are to use the same pathway for the whole building.

Please note: A NABERS Embodied Carbon pathway that uses a project's NABERS Embodied Carbon rating will be available in future and will include details of a transition phase to being the primary way in which Green Star projects demonstrate outcomes in this credit. The Benchmark and Reference buildings pathways both reference NABERS rules for consistency across the pathways, and these rules apply despite the NABERS pathway not yet existing in this rating tool.

Project teams seeking recognition for achieving a NABERS rating for upfront embodied carbon before the Green Star Buildings pathway is released should do so via a Technical Question.

## <mark style="color:$primary;">Criteria</mark>

#### ***Pathway A: Benchmark pathway***

<mark style="color:$success;">**Minimum Expectation — Nil**</mark>

* [#id-24a.0.1-reducing-upfront-carbon-emissions](#id-24a.0.1-reducing-upfront-carbon-emissions "mention"): The building's upfront carbon emissions are at least 10% less than a benchmark.

<mark style="color:$success;">**Credit Achievement — Up to 3 points**</mark>

In conjunction with *Minimum Expectation:*

* [#id-24a.1.1-reducing-upfront-carbon-emissions](#id-24a.1.1-reducing-upfront-carbon-emissions "mention"): The building's upfront carbon emissions are at least 20% less than a benchmark.
* [#id-24a.1.2-existing-building-compensation](#id-24a.1.2-existing-building-compensation "mention"): Demolition of existing buildings less than 50 years old are offset.

<mark style="color:$success;">**Exceptional Performance — Up to 3 points**</mark>

In conjunction with *Credit Achievement:*

* [#id-24a.2.1-reducing-upfront-carbon-emissions](#id-24a.2.1-reducing-upfront-carbon-emissions "mention"): The building's upfront carbon emissions are at least 40% less than a benchmark.

#### ***Pathway B: Reference building pathway***

<mark style="color:$success;">**Minimum Expectation — Nil**</mark>

* [#id-24b.0.1-reducing-upfront-carbon-emissions](#id-24b.0.1-reducing-upfront-carbon-emissions "mention"): The building's upfront carbon emissions are at least 10% less than a reference building.

<mark style="color:$success;">**Credit Achievement — Up to 3 points**</mark>

In conjunction with *Minimum Expectation:*

* [#id-24b.1.1-reducing-upfront-carbon-emissions](#id-24b.1.1-reducing-upfront-carbon-emissions "mention"): The building's upfront carbon emissions are at least 20% less than a reference building.
* [#id-24b.1.2-existing-building-compensation](#id-24b.1.2-existing-building-compensation "mention"): Demolition of existing buildings less than 50 years old are offset.

<mark style="color:$success;">**Exceptional Performance — Up to 3 points**</mark>

In conjunction with *Credit Achievement:*

* [#id-24b.2.1-reducing-upfront-carbon-emissions](#id-24b.2.1-reducing-upfront-carbon-emissions "mention"): The building's upfront carbon emissions are at least 40% less than a reference building.

#### ***Pathway C: NABERS Embodied Carbon pathway***

<mark style="color:$success;">**Minimum Expectation — Nil**</mark>

In development

<mark style="color:$success;">**Credit Achievement — Up to 3 points**</mark>

In development

<mark style="color:$success;">**Exceptional Performance — Up to 3 points**</mark>

In development

***

## <mark style="color:$primary;">Additional information</mark>

#### Scope of credit

All areas in the control of the building owner. Refer to the [*NABERS Embodied Carbon Rules*](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules) for further guidance on minimum material coverage. For building types not included in the NABERS Embodied Carbon Rules, projects are to include the structure, envelope and systems as a minimum. This scope is applicable for all pathways in this credit.

In tenanted buildings, upfront carbon emissions from fitout works are considered in the Upfront Fitout Emissions sector specific credit.

#### Stage implementation

**Strategy** | **Brief** | **Concept** | **Design** | Tender | Construction | Handover | Use

#### Synergies with other credits

* Energy Use
* Disclosure of Impacts
* Responsible Structure
* Responsible Envelope
* Responsible Systems

#### Sustainable Development Goals

* **Goal 7:** Affordable and Clean Energy
* **Goal 13:** Climate Action

#### Relevant reporting initiatives

* GRESB
* Task Force on Climate-related Financial Disclosures **(TCFD)**

***

## <mark style="color:$primary;">Alternative pathways</mark>&#x20;

Where there are alternative pathways that a project can follow to achieve the credit, or sector specific alternatives.&#x20;

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Alternative pathways</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

***

## <mark style="color:$primary;">Clarifications</mark>

Where GBCA have clarified any requirements of the credit criteria. This information is additional and it is not complusory to apply.

These were previously referred to as *Frequently Asked Questions*.&#x20;

<details>

<summary>Clarifications</summary>

Existing FAQs are currently located [*here*](https://www.gbca.org.au/greenstar-manager/faqs/). GBCA are working on bringing them across to this site. New FAQs will be published here under the relevant credit and type.

</details>

{% tabs %}
{% tab title="Pathway A: Benchmark pathway" %}

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Minimum Expectation</mark>

The project must comply with the following criterion:

* Reducing Upfront Carbon Emissions

#### 24A.0.1 Reducing Upfront Carbon Emissions

The building's upfront carbon emissions are at least 10% less than the following benchmarks:

| Building class                 | Benchmark                |
| ------------------------------ | ------------------------ |
| Class 2 Apartments             | 800 kgCO2e/m<sup>2</sup> |
| Class 5 Commercial             | 700 kgCO2e/m<sup>2</sup> |
| Class 7b Warehouse and storage | 450 kgCO2e/m<sup>2</sup> |

#### *Calculating upfront carbon emission reductions*

An accredited NABERS Assessor calculates the building's upfront carbon emissions by completing the *Upfront Carbon Reduction calculator* in accordance with the [*NABERS Embodied Carbon rules*](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules)*.* This includes how stored biogenic carbon and carbon neutral products do not contribute to upfront carbon emission reductions and when product-specific emission factors and the default emission factors from the *NABERS National material emission factors database* are used. The rules in Chapter 8 of the *NABERS Embodied Carbon rules* may be amended such that all materials can be considered non-key materials and acceptable estimates outlined in Section 8.3.5 can be used. Refer *Guidance* for further information.

#### *Quality assurance*

The initial NABERS Assessor provides a signed verification that the *Upfront Carbon Reduction calculator* has been completed in accordance with the approach prescribed in this pathway and the relevant documentation has been used.

The *Upfront Carbon Reduction calculator* and associated documentation is peer reviewed and signed off by an independent, accredited NABERS Assessor.

### <mark style="color:$success;">Credit Achievement</mark>

In conjunction with *Minimum Expectation*, the project must comply with **both** of the following criteria:

* Reducing Upfront Carbon Emissions
* Existing Building Compensation

#### 24A.1.1 Reducing Upfront Carbon Emissions

The building's upfront carbon emissions are at least 20% less than a benchmark.

Refer [*Minimum Expectation*](#id-24a.0.1-reducing-upfront-carbon-emissions) for the benchmarks and for further information on calculating upfront carbon emission reductions and quality assurance.

Stepped points are available for upfront carbon reductions between 10% to 20% as below. Projects meeting the Climate Positive Pathway must demonstrate at least 20% less than the relevant benchmark for this performance level.

<table><thead><tr><th width="250.25">Available points</th><th>Percentage requirements</th></tr></thead><tbody><tr><td>1 point</td><td>At least <strong>13%</strong> less upfront carbon emissions than the relevant benchmark.</td></tr><tr><td>1 additional point</td><td>At least <strong>16%</strong> less upfront carbon emissions than the relevant benchmark.</td></tr><tr><td>1 additional point</td><td>At least <strong>20%</strong> less upfront carbon emissions than the relevant benchmark.</td></tr></tbody></table>

#### 24A.1.2 Existing Building Compensation

Where an existing building within the control of the building owner is less than 50 years old and has been fully or partly demolished for construction, the embodied carbon of the demolished portion is compensated for with offsets. Beyond 50 years, there are no requirements.

#### *Calculating embodied carbon emissions of the demolished portion*

The embodied carbon of the demolished portion of the existing building is determined by one of the following:

* Using the benchmarks in [*Minimum Expectation*](#id-24a.0.1-reducing-upfront-carbon-emissions) and the GFA of the demolished portion.
* Using data or drawings of the existing building to determine quantities.

This is calculated using *Upfront Carbon Reduction calculator*.

#### *Addressing emissions*

Where the existing building is 30 years old or less, 100% of the embodied carbon emissions associated with the demolished portion are offset.

Where the existing building is between 30 to 50 years old, the embodied carbon emissions associated with the demolished portion that are offset are discounted at 10% for every two additional years past year 30.

The purchased offsets are nature-based and produced by a GBCA recognised entity. Further information is available in [*Climate positive buildings and our net zero ambitions*](https://gbca-web.s3.amazonaws.com/media/documents/climate-positive-buildings-net-zero-ambitions_Z3pcK5R.pdf).

### <mark style="color:$success;">Exceptional Performance</mark>

In conjunction with the *Credit Achievement*, the project must comply with the following criteria:

* Reducing Upfront Carbon Emissions

#### 24A.2.1 Reducing Upfront Carbon Emissions

The building's upfront carbon emissions are at least 40% less than a benchmark.

Refer [*Minimum Expectation*](#id-24a.0.1-reducing-upfront-carbon-emissions) for the benchmarks and further information on calculating upfront carbon emission reductions and quality assurance.

Stepped points are available for upfront carbon reductions between 20% to 40% as below. Projects meeting the Climate Positive Pathway must demonstrate at least 40% less than the relevant benchmark for this performance level.

<table><thead><tr><th width="231.5">Available points</th><th>Percentage requirements</th></tr></thead><tbody><tr><td>1 point</td><td>At least <strong>26%</strong> less upfront carbon emissions than the relevant benchmark.</td></tr><tr><td>1 additional point</td><td>At least <strong>33%</strong> less upfront carbon emissions than the relevant benchmark.</td></tr><tr><td>1 additional point</td><td>At least <strong>40%</strong> less upfront carbon emissions than the relevant benchmark.</td></tr></tbody></table>

***

## <mark style="color:$primary;">Definitions</mark>

Definitions provided here must be applied to Requirements unless agreed with GBCA via a Technical Question.

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#accredited-nabers-assessor)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#independent-accredited-nabers-assessor)

***

## <mark style="color:$primary;">Guidance</mark>

Guidance is supporting information for the credit requirements and is not mandatory to apply.

**Benchmarks**\
The benchmarks proposed in this pathway are based on a review of the data collected from Green Star Buildings v1 submissions to date. The benchmarks have been provided for the building classes where sufficient data was available and based on the average emissions intensity of the Reference Project from a variety of submissions. An uplift factor was included to ensure projects continue to demonstrate upfront carbon reductions that align with the Intergovernmental Panel on Climate Change (IPCC) recommendations on the built environment.

Overtime, benchmarks for other building classes may become available based on the data that can be collected or will be superseded by the *NABERS Embodied Carbon pathway.*

**Calculating upfront carbon emissions reduction**\
The rules outlined in Chapter 8 Material quantities in the [*NABERS Embodied Carbon Rules*](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules) can be amended such that all materials can be considered non-key materials. This means that as-built data is not mandatory to demonstrate the quantity of key materials and to use product-specific emission factors but instead, acceptable estimates as outlined in Section 8.3.5 can be used to demonstrate the as-built quantities. Evidence of product-specific emission factors is still to be provided.

*Carbon neutral products*\
The upfront carbon (modules A1 to A3) of products certified under the Climate Active Carbon Neutral Standard may be used however any offsets will not contribute to the upfront carbon reduction of the project. Refer to Chapter 9.4 and 10 in the [*NABERS Embodied Carbon Rules*](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules) for further information. The offsets made as part of the Climate Active Carbon Neutral certification are recognised under the [*Upfront Carbon Compensation*](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/positive-3/25-or-upfront-carbon-compensation.md) credit.

*Bio-based materials*\
Stored biogenic carbon from bio-based materials cannot be used to reduce the carbon for another product or other modules and is only recognised under the [*Upfront Carbon Compensation*](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/positive-3/25-or-upfront-carbon-compensation.md) credit.

**Absent existing building data**\
In the absence of available data or drawings of the existing building, the existing building can be assumed to follow current NCC compliant construction techniques. The project teams must justify any simplifications or approximations made.

***

## <mark style="color:$primary;">Submission content</mark>

Submissions for this credit must contain:

* **Submission form** through Green Star Online
* **Upfront Carbon Reduction calculator**
* **Evidence** to support claims made in the submission

#### Recommended evidence

The following list of evidence serves as a guide for the Certified submission and is not exhaustive. Project teams are not required to provide all of the listed items and alternate forms of documentation can be used to demonstrate compliance. The key requirement is that evidence is provided to support each claim.

**Reducing Upfront Carbon Emissions**

* NABERS Assessor accreditation from both the initial assessor and the peer reviewer.
* Sign off from the initial assessor and peer reviewer, verifying the calculator has been completed in accordance with the approach in this pathway.

**Existing Building Compensation**

* As built drawings or similar of the existing building.
* Demolition drawings.
* Evidence of the age of the existing building.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

***

## <mark style="color:$primary;">Supporting information</mark>

The following document(s) are referenced in this credit:

* GBCA – [Climate positive buildings and our net zero ambitions](https://gbca-web.s3.amazonaws.com/media/documents/climate-positive-buildings-net-zero-ambitions_Z3pcK5R.pdf)
* GBCA – [Upfront Carbon calculation guide](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/calculation-guides/upfront-carbon-calculation-guide.md)
* NABERS – [Find an Accredited Assessor](https://www.nabers.gov.au/ratings/find-accredited-assessor)
* NABERS – [NABERS Embodied Carbon Rules](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules)
* NABERS – [National material emission factors database](https://www.nabers.gov.au/publications/national-emission-factors-database)
  {% endtab %}

{% tab title="Pathway B: Reference building pathway" %}

***

## <mark style="color:$primary;">Requirements</mark>

### <mark style="color:$success;">Minimum Expectation</mark>

The project must comply with the following criteria:

* Reducing Upfront Carbon Emissions

#### 24B.0.1 Reducing Upfront Carbon Emissions

The building's upfront carbon emissions are at least 10% less than a reference building.

#### *Calculating upfront carbon emission reductions*

The upfront carbon emission reductions are calculated by completing one of the following:

* The *Upfront Carbon Reduction calculator* for the reference building and proposed building.
* A comparative Life Cycle Assessment (LCA) and reporting the climate change impact category for modules A1 to A5, as defined by EN 15978, for a reference building and the proposed building. Refer to the [*Impacts Disclosure*](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/responsible/10-or-impacts-disclosure.md#quality-assurance) credit for LCA data and quality assurance requirements.

The reference building is defined as per the [*Upfront Carbon calculation guide*](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/calculation-guides/upfront-carbon-calculation-guide.md). Assumptions are disclosed by completing the *Upfront Carbon modelling report template*. Where a project deviates from the default material specifications in the *Upfront Carbon calculation guide*, it is peer reviewed by an independent experienced professional.

The upfront carbon of the proposed building is calculated in accordance with the [*NABERS Embodied Carbon rules*](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules). This includes how stored biogenic carbon and carbon neutral products do not contribute to upfront carbon emission reductions and the *NABERS National material emission factors database* is used. The rules in Chapter 8 of the *NABERS Embodied Carbon rules* may be amended such that all materials can be considered non-key materials and acceptable estimates outlined in Section 8.3.5 can be used. Refer *Guidance* in the *Upfront Carbon Reduction – Pathway A: Benchmark pathway* for further information.

### <mark style="color:$success;">Credit Achievement</mark>

In conjunction with *Minimum Expectation*, the project must comply with **both** of the following criteria:

* Reducing Upfront Carbon Emissions
* Existing Building Compensation

#### 24B.1.1 Reducing Upfront Carbon Emissions

The building's upfront carbon emissions are at least 20% less than a reference building.

Refer [*Minimum Expectation*](#calculating-upfront-carbon-emission-reductions-1) for further information on calculating upfront carbon emission reductions.

Stepped points are available for upfront carbon reductions between 10% to 20% as below. Projects meeting the *Climate Positive Pathway* must demonstrate at least 20% less than a reference building for this performance level.

<table><thead><tr><th width="230.25">Available points</th><th>Percentage requirements</th></tr></thead><tbody><tr><td>1 point</td><td>At least <strong>13%</strong> less upfront carbon emissions than a reference building.</td></tr><tr><td>1 additional point</td><td>At least <strong>16%</strong> less upfront carbon emissions than a reference building.</td></tr><tr><td>1 additional point</td><td>At least <strong>20%</strong> less upfront carbon emissions than a reference building</td></tr></tbody></table>

#### 24B.1.2 Existing Building Compensation

Refer [*Existing Building Compensation*](#id-24a.1.2-existing-building-compensation) in *Credit Achievement* in the *Upfront Carbon Reduction – Pathway A: Benchmark pathway* for requirements.

### <mark style="color:$success;">Exceptional Performance</mark>

In conjunction with the *Credit Achievement*, the project must comply with the following criteria:

* Reducing Upfront Carbon Emissions

#### 24B.2.1 Reducing Upfront Carbon Emissions

The building's upfront carbon emissions are at least 40% less than a reference building.

Refer [*Minimum Expectation*](#calculating-upfront-carbon-emission-reductions) for further information on calculating upfront carbon emission reductions.

Stepped points are available for upfront carbon reductions between 20% to 40% as below. Projects meeting the Climate Positive Pathway must demonstrate at least 40% less than a reference building for this performance level.

<table><thead><tr><th width="225.25">Available points</th><th>Percentage requirements</th></tr></thead><tbody><tr><td>1 point</td><td>At least <strong>26%</strong> less upfront carbon emissions than a reference building.</td></tr><tr><td>1 additional point</td><td>At least <strong>33%</strong> less upfront carbon emissions than a reference building.</td></tr><tr><td>1 additional point</td><td>At least <strong>40%</strong> less upfront carbon emissions than a reference building.</td></tr></tbody></table>

***

## <mark style="color:$primary;">Definitions</mark>

Definitions provided here must be applied to Requirements unless agreed with GBCA via a Technical Question.

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#independent-experienced-individual)

[Glossary](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/all-definitions.md#reference-building)

***

## <mark style="color:$primary;">Guidance</mark>

Guidance is supporting information for credit requirements and not mandatory to apply.

**Calculating upfront carbon emissions reduction**\
The rules outlined in Chapter 8 Material quantities in the [*NABERS Embodied Carbon rules*](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules) can be amended such that all materials can be considered non-key materials. This means that as-built data is not mandatory to demonstrate the quantity of key materials and to use product-specific emission factors but instead, acceptable estimates as outlined in Section 8.3.5 can be used to demonstrate the as-built quantities. Evidence of product-specific emission factors is still to be provided.

*Carbon neutral products*\
The upfront carbon (modules A1 to A3) of products certified under the Climate Active Carbon Neutral Standard may be used however any offsets will not contribute to the upfront carbon reduction of the project. Refer to Chapter 9.4 and 10 in the [*NABERS Embodied Carbon rules*](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules)for further information. The offsets made as part of the Climate Active Carbon Neutral certification are recognised under the Upfront Carbon Compensation credit.

*Bio-based materials*\
Stored biogenic carbon from bio-based materials cannot be used to reduce the carbon for another product or other modules and is only recognised under the Upfront Carbon Compensation credit.

**Social infrastructure projects**\
Social infrastructure projects, such as schools and hospitals, should refer to the Infrastructure & Transport Ministers' Meetings (ITMM) [Embodied Carbon Measurement for Infrastructure: Technical Guidance](https://www.infrastructure.gov.au/infrastructure-transport-vehicles/net-zero/working-states-and-territories-decarbonise-infrastructure-and-transport#:~:text=The%20Embodied%20Carbon%20Measurement%20for%20Infrastructure%3A%20Technical%20Guidance,their%20advisors%2C%20delivery%20partners%2C%20and%20emissions%20tool%20vendors.) and Infrastructure NSW's [Embodied Carbon Measurement for Infrastructure: Technical Guidance](https://www.infrastructure.nsw.gov.au/media/ak2o0bqg/embodied-carbon-measurement-technical-guide_april-2025.pdf) when developing the Reference building. Refer to Section 5 in both documents for guidance.

***

## <mark style="color:$primary;">Submission content</mark>

Submissions for this credit must contain:

* **Submission form** through Green Star Online
* **Upfront Carbon modelling report**
* **Upfront Carbon Reduction calculator**
* **Evidence** to support claims made in the submission

#### Recommended evidence

The following list of evidence serves as a guide for the Certified submission and is not exhaustive. Project teams are not required to provide all of the listed items and alternate forms of documentation can be used to demonstrate compliance. The key requirement is that evidence is provided to support each claim.

**Reducing Upfront Carbon Emissions**

* As built drawings
* As built building quantities such as as built bill of quantities, quantities summary from material supplier or similar.
* Product data sheets such as an Environmental Product Declaration.
* Peer review statement from independent experienced individual and relevant credentials.
* Extracts from LCA report of the reference and proposed building including a comparison table of material changes.
* Comparison table of the key material changes that have contributed towards the upfront carbon reductions, this is to include the carbon intensity of each material.
* LCA peer review statement.
* LCA practitioner competencies statement or LCACP certificate for practitioner and peer reviewer.

**Existing Building Compensation**

* As built drawings or similar of the existing building and demolition drawings.
* Evidence of the age of the existing building.

Refer to the [Guidance for Submitting for Designed Assessments](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/other-useful-resources/guidance-for-submitting-for-designed-assessments.md) for further information on submitting evidence for the Designed assessment.

***

## <mark style="color:$primary;">Supporting information</mark>

The following document(s) are referenced in this credit:

* GBCA – [Climate positive buildings and our net zero ambitions](https://gbca-web.s3.amazonaws.com/media/documents/climate-positive-buildings-net-zero-ambitions_Z3pcK5R.pdf)
* GBCA – [Upfront Carbon calculation guide](https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/calculation-guides/upfront-carbon-calculation-guide.md)
* Infrastructure and Transport Ministers - [Embodied Carbon Measurement for Infrastructure: Technical Guidance](https://www.infrastructure.gov.au/sites/default/files/documents/embodied-carbon-measurement-for-infrastructure.pdf)
* Infrastructure NSW - [Embodied Carbon Measurement for Infrastructure: Technical Guidance](https://www.infrastructure.nsw.gov.au/media/ak2o0bqg/embodied-carbon-measurement-technical-guide_april-2025.pdf)
* NABERS – [NABERS Embodied Carbon Rules](https://www.nabers.gov.au/publications/nabers-embodied-carbon-rules)
* NABERS – [National material emission factors database](https://www.nabers.gov.au/publications/national-emission-factors-database)
  {% endtab %}
  {% endtabs %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://greenstarresources.gbca.au/greenstarresources.gbca.au_ratingtools/current-green-star-rating-tools/green-star-buildings/v1.1/categories-and-credits/positive-3/24-or-upfront-carbon-reduction.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.